SYSTEM AREA
PGM OUTPUTS
PC4216 Custom
This section is for programming each of the 9 custom groups for different options. Each group
can be programmed with 16 outputs from the 28 listed options. The PC4216 modules can then be
assigned to one of these groups.
4580 Automation Items
This programming section allows the panel to have control over the Escort 4580s (Voice
Prompting Module) Automation outputs. Each of the 32 Automation output Modules may be
programmed to follow one of the 35 Programmable Outputs that are available to the panel (See
PGM Output List for a listing and description of each of the PGM Output options).
The Automation Output Control Module (Power House PL513) use the existing AC power lines of
the building to transfer data to the Automation Output modules controlling when an output will
activate or deactivate. The output modules are then connected to devices such as lamps. Refer
to the Escort 4580 manual for programming Item Options and Output Conditions.
PGM Pulse Times
This section will allow you to select the amount of time the PGM output will remain active after
being triggered.
The main bell, switched auxiliary or any of the PGM outputs programmed for “Utility Output”,
“Sensor Reset” and “Duress”, can be active for 000 to 255 seconds. The default setting is 005.
Any output programmed for “Kissoff Output” can be active for 000 to 255 seconds. The default
setting is 003.
Any output programmed for “Ground Start” can be active for 000 to 255 seconds. The default
setting is 002.
Note: The panel will wait until the end of the Ground Start before dialing.
Any output programmed for “Chime Pulse” can be active for 000 to 255 seconds. The default
setting is 002.
The Duress Pulse time is the programmable amount of time from 000 - 255 seconds that the
Duress Pulse Programmable output will activate for when a duress code is entered. The default
value is 005 Seconds.
4216 CUSTOM
(3)
CUSTOM GROUP
(01)
(09)
4580 AUTO ITEMS
(01) (32)
PGM PULSE TIMES
(5)
UTILITY/SENSOR
(0)
KISSOFF PULSE
(1)
GROUND START
(2)
CHIME PULSE
(3)
DURESS PULSE
(5)