PARTITION AREA
ADD/EDIT PAR
ZONE ASSIGNMENT
Exit Delay Termination?
YES = During the exit delay if a Standard Delay zone is tripped and restored then the exit delay
will be reduced to 5 seconds. Audible Exit Delay and Exit Delay Squawk will be terminated
upon the restoral of the standard delay zone. At the end of the shortened exit delay all
functions will return to normal, and the partition will be armed.
NO = The exit delay will count down for the full programmed duration.
Global Alarm Annunciation?
YES = This system toggle will allow the partition keypads to sound the buzzer (5 seconds on and
5 seconds off) and display the message "Partition X In Alarm" (where Partition X is the
programmed label of the partition) when any other partition is in alarm. The buzzer will be
silenced and the message cleared form the keypad display when the alarm has been
silenced or any key is pressed on the keypad. By default this option is set to No.
NO = No notification of the alarm will be given on the Global Keypad.
Note: It is recommended that global alarm annunciation is enabled on multi partition systems.
Full System Status Enunciator
Yes = Enables the Partition Status Enunciator on partition keypads. Partition keypads will display
the status of all active partitions on the system.
No = Partition keypads will not display the Partition Status Enunciator.
Note: This option overrides the clock display option.
Partition Times
The following programming sections are for programming various times separately for each
partition.
The keypads will give a tone to signal an entry delay when a Standard Delay zone or a Delay
Home Away zone is activated. This gives the user time to disarm the system when they enter
through a door. The entry delay time is programmable from 000 to 255 seconds (see Standard
Delay zones and Delay Home Away Zone Types). The default setting is 030.
When a system is armed, the zones will not become active until the exit delay has expired, this
gives the user time to exit the building without tripping alarms. The exit delay time is
programmable from 000 to 255 seconds. This time can be displayed on the keypad (see “Disp
Exit Time). The default setting is 120.
This entry time is for auxiliary delay zones, for doorways that may need a longer entry delay than
standard delay zones. This time is programmable from 000 to 255 seconds (See Auxiliary Delay
Zone Types). The default setting is 045.
This exit time is for auxiliary delay zones, for doorways that may need a longer exit delay than
standard delay zones. This time is programmable from 000 to 255 seconds (See Auxiliary Delay
Zone Types.). The default setting is 120.
Note: The auxiliary entry/exit delays should not be shorter than the standard entry/exit
delay times.
This is the amount of time the panel will wait before CTT arming. Valid entries are from 000 to 255.
The timer value is the programmed value multiplied by 5 minutes. Programming a value of 000 will
disable this feature.
- The CTT timer will begin when the partition is disarmed.
- 15 minutes before the CTT arming takes place, the CTT arming prealert will begin. The keypads
will beep once every 4 seconds and the keypads will display the message
CTT ARMING
IN PROGRESS...
- At 5 minutes before the CTT arming takes place the keypads will beep twice every four
seconds (urgency)
- At 1 minute before the CTT arming the panel will begin the normal autoarm procedure.
If a valid access code with the disarmed bit enabled is entered during the CTT arming prealert, a user
log will be logged to the event buffer and the CTT timer will be set to 1 hour. If the access code is
entered during the autoarm prealert, the panel will log and transmit an autoarm abort reporting code.
Notes: For the CTT arming feature to function properly, the autoarm abort requires access
code option must be enabled.
During the CTT arming prealert, the Escort4580 will prompt the user with autoarm active.
EXIT DELAY
TERMINATION
N
GLOB ALM ANNUN
N
EXIT DELAY
(1)
AUX ENTRY DELAY
(2)
AUX EXIT DELAY
(3)
PARTITION TIMES
(2)
ENTRY DELAY
(0)
FULL SYS. STAT
N
CTT TIME
(4)