EasyManua.ls Logo

DSC MAXSYS PC4010 - Page 51

DSC MAXSYS PC4010
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
PARTITION AREA
ADD/EDIT PAR
WHICH PARTITION
Auto Arm Squawk?
YES = The bell output will activate for one second every ten seconds during the autoarm
prealert.
NO = The bell output will not activate during autoarm prealert.
Bell Squawk On?
YES = The bell output will activate once briefly when the partition is armed, twice when
disarmed. Only the bell terminals on the PC4010 main board, when programmed for
“Fire and Burg”, “Inv Fire/Burg”, “Burg Only” or “Inv Burg Only”, will squawk.
NO = Bell Squawk disabled.
Keypad Lockout?
YES = Keypad Lockout enabled.
NO = Keypad Lockout disabled.
(See “TOTAL BAD CODES”, “LOCKOUT DURATION” and “LOCKOUT REP CODE”.)
Utility Output requires an Access Code?
YES = Utility output requires a valid access code - [Q][7][access code].
NO = No access code required - [Q][7].
(See “UTILITY OUTPUT”.)
Sensor Reset requires an Access Code?
YES = Sensor Reset Requires Code - [Q][4][access code].
NO = Sensor Reset does not require a code - [Q][4].
(See “SENSOR RESET”.)
User Functions Any Code?
YES = User functions require [Q][6][any code].
NO = User functions require [Q][6][Master Code]. This means a Grand Master, System Master
or a Supervisory Code assigned to that partition.
Audible Exit Urgency?
YES = 1 beep every second on keypad. During the last 10 seconds, keypad will beep 3 times per
second.
NO = Keypad is silent during exit delay.
Bell Squawk Exit Delay?
YES = Bell squawks once every second on exit delay. During the last 10 seconds, bell will
squawk twice every second.
NO = Silent bell on exit delay.
Audible Exit Fault?
YES = A standard delay will sound the siren for entry delay if zone is still violated at the end of
exit delay.
NO = Siren will not be on for entry delay if zone is still violated at the end of exit delay.
Urgency During the Exit Delay?
YES = During the last 10 seconds of entry delay, keypad beeps 3 times per second.
NO = Keypad entry is steady.
Bell Squawk Entry Delay?
YES = Bell squawks once every second on entry delay. During the last 10 seconds, bell will
squawk twice every second.
NO = Bell is silent during entry delay.
AUTOARM SQUAWK
N
BELL SQUAWK ON
N
KYPD LOCKOUT?
N
UTIL REQ CODE
N
SEN RES REQ CD
N
USER FN ANY CD
N
AUD.EXIT URGEN
N
SQUAWK EX.DEL
N
AUD.EXIT FAULT
N
URG.ENTRY DEL
N
SQUAWK EN.DEL
N