EasyManuals Logo

DSC MAXSYS PC4010 Programming Manual

DSC MAXSYS PC4010
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
11
Keypad Toggle Options
Programming the operation of the 3 keypad emergency keys ([F], [A] and [P]). Toggle options are
in the form of questions. Use the [Q] key to toggle between Yes and No to enable or disable the
feature. Use the [<][>] keys to scroll through the options. Regardless of programming each key
must be pressed for 2 seconds before the alarm will be activated.
[F] key activates the Bell Outputs?
YES = The bell output will activate when the [F] key is pressed.
NO = The bell output will not activate when the [F] key is pressed.
The bell output for the [F] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Fire Only and Inv Fire Only.
[F] key pulses the Bell Output?
YES = The bell output, if enabled, will pulse when the [F] key is pressed.
NO = The bell output, if enabled, will be steady when the [F] key is pressed.
The bell output for the [F] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Fire Only and Inv Fire Only.
The keypad beeps when the [F] key is pressed?
YES = The keypad will beep 3 times when the [F] key has been pressed for 2 seconds.
NO = The keypad will not sound when the [F] key is pressed.
The bell is silent when the [A] key is pressed?
YES = The bell output will not activate when the [A] key is pressed.
NO = The bell output will activate when the [A] key is pressed.
The bell output for the [A] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Burg Only and Inv Burg Only.
The bell is steady when the [A] key is pressed?
YES = The bell output, if enabled, will be steady when the [A] key is pressed.
NO = The bell output, if enabled, will pulse when the [A] key is pressed.
The bell output for the [A] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Burg Only and Inv Burg Only.
The keypad beeps when the [A] key is pressed?
YES = The keypad will beep 3 times when the [A] key has been pressed for 2 seconds.
NO = The keypad will not sound when the [A] key is pressed.
[P] key activates the Bell Outputs?
YES = The bell output will not activate when the [P] key is pressed.
NO = The bell output will activate when the [P] key is pressed.
The bell output for the [P] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Burg Only and Inv Burg Only.
The bell is steady when the [P] key is pressed?
YES = The bell output, if enabled, will be steady when the [P] key is pressed.
NO = The bell output, if enabled, will pulse when the [P] key is pressed.
The bell output for the [P] key is any output (Bell, SW Aux or PGM) that is programmed for Fire
and Burg, Inv Fire and Burg, Burg Only and Inv Burg Only.
The keypad does not beep when the [P] key is pressed?
YES = The keypad will not sound when the [P] key is pressed.
NO = The keypad will beep 3 times when the [P] key has been pressed for 2 seconds.
SYSTEM AREA
SYSTEM OPTIONS
KEYPAD TOG OP T/KYPD LOCKOUT OP T/SYSTEM TIMES
KEYPAD TOG OPT
(1)
[F] BELL
Y
[F] PULSE BELL
Y
[F] BUZZER
Y
[A] SIL BELL
Y
[A] STDY BELL
Y
[A] AUD BUZZ
N
[P] SIL BELL
Y
[P] STDY BELL
Y
[P] SILENT BUZ
Y

Other manuals for DSC MAXSYS PC4010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4010 and is the answer not in the manual?

DSC MAXSYS PC4010 Specifications

General IconGeneral
BrandDSC
ModelMAXSYS PC4010
CategorySecurity System
LanguageEnglish

Related product manuals