PGM
OUTPUTS LIST
SYSTEM AREA
PGM OUTPUTS
The output will activate when any fire or zone alarm occurs on any of the selected partitions.
The output will deactivate when any fire or zone alarm occurs on any of the selected partitions.
The output will activate when any zone alarm occurs on any of the selected partitions.
The output will deactivate when any zone alarm occurs on any of the selected partitions.
The output will activate when any fire alarm occurs on any of the selected partitions.
The output will deactivate when any fire alarm occurs on any of the selected partitions.
The output will activate when [Q][7] is entered on any keypad on any of the selected partitions.
Note: This output will follow the “Utility/Sensor” PGM pulse time.
The output will deactivate when [Q][4] is entered on any keypad on any of the selected partitions.
Note: This output will follow the “Utility/Sensor” PGM pulse time.
The output will activate when any of the selected partitions are armed.
The output will activate when any alarm occurs on any of the selected partitions. The output will
stay activated until the partition that caused the alarm is disarmed.
The output will activate when a trouble condition is present on any of the selected partitions.
If a system trouble occurs (i.e. loss of time, TLM) all trouble outputs will activate.
The output will activate during exit and entry delay on any of the selected partitions.
The output will activate when door chime is activated on any of the selected partitions, and
deactivate when the chime pulse timer expires. (See “CHIME PULSE” under “PGM PULSE
TIMES”.)
Door chime activates when a zone is opened and activates again when a zone is closed. For Door
Chime to activate, the user must enable the door chime (see “DOOR CHIME” under [Q][6] User
Functions in the System Manual) and the installer will enable door chime for the individual zones
(see “CHIME FUNCTION” under “ZONE OPTIONS”).
The output will activate when a telephone line trouble is present.
FIRE AND BURG
(00)
INV FIRE/BURG
(01)
BURG ONLY
(02)
INV BURG ONLY
(03)
FIRE ONLY
(04)
INV FIRE ONLY
(05)
UTILITY OUTPUT
(06)
SENSOR RESET
(07)
PARTITION STATUS
(08)
LATCHED STROBE
(09)
TROUBLE OUTPUT
(10)
COURTESY PULSE
(11)
CHIME FOLLOWER
(12)
TLM ONLY
(13)