SYSTEM AREA
PGM OUTPUTS
The output will activate when a Telephone Line Trouble is present and an alarm occurs on any of
the selected partitions.
The output will activate when a Failure to Communicate Trouble is present. The output will stay
activated until the trouble is cleared by the user or a successful communication is sent to the
central station.
The output will activate while the panel is attempting to communicate with the central station.
The output will activate for a programmable number of seconds before the panel attempts to
communicate with the central station. See ‘PGM Pulse Times’.
Note: This output will follow the “Ground Pulse” PGM pulse time.
The output will activate for a programmable number of seconds after a successful communication
to the central station. See ‘PGM Pulse Times’.
Note: This output will follow the “Kissoff Pulse” PGM pulse time.
This output will remain active at all times unless a system reset is ordered by the main panel.
The output will activate when all the zones in the partition are closed, and the partition is
disarmed. If a zone opens or the partition is armed, the output will deactivate.
This output will annunciate when a selected zone has gone into alarm.
Any one of the 64 zones can be selected. If the zone is armed and goes into alarm, the output will
activate and remain active, even when the partition the zone belongs to has been disarmed. The
output will remain active until the partition is armed again.
This output will follow a selected zone. Any one of the possible 64 zones can be selected. If the
zone is opened, the output will activate. When the zone is closed the output will deactivate.
See ‘Follows + Alarms’ for enabling the output to be a zone follower and zone alarm annunciator.
This output will be turned on when a duress type code is used to perform any function. It will
follow the utility output timer.
Note: This output will follow the Utility/Sensor Reset PGM pulse time.
This output will activate when a programmed partition(s) keypad buzzer activates for Entry Delays,
Auto Arm Prealert, 24 Hour Buzzer and Door Strike.
This option can be remotely activated with DLS-1 (version 5.4 or later), and remain active until
deactivated by the DLS-1 package.
This option will follow the exit delay timer of the partition(s) it is assigned to.
This option will follow the entry delay timer of the partition(s) it is assigned to.
This output type may be programmed to follow any of 99 Date Schedule (See Event Scheduling)
The schedule Number (01-99) which the output is programmed to follow may be activated at any
time (Start Time) and remain on until an End Time occurs for the schedule. Pulse Timer The on
time duration of the Date Schedule output (Pulse Timer) may be programmed in seconds. Once
the schedule number has bee selected the panel will prompt for a 2 digit entry between 00 and
59s. If a number between 01 and 59 is entered the output will remain on for that number of
seconds. If 00 is enter in this section the output will follow the Date Schedule Interval timer for
both Start Time and End Time. See Event Scheduling for programming detail of the Date
Schedules and Intervals.
TLM AND ALARM
(14)
FAILURE TO COMM
(15)
COMMS ACTIVE
(16)
GROUND START
(17)
KISSOFF OUTPUT
(18)
COMBUS POWER
(19)
READY STATUS
(20)
ZONE ALARM
(21)
ZONE FOLLOW
(22)
DURESS OUTPUT
(23)
BUZZER FOLLOW
(24)
REMOTE OPERATION
(25)
EXIT FOLLOW
(26)
ENTRY FOLLOW
(27)
DATE SCHEDULE
(28)