SYSTEM AREA
COMMUNICATOR
COMMS TOGGLES
Communicator Toggles
Selecting options relevant to the communications of the panel. Toggle options given in the form of
a question. Use the [Q] key to toggle between [Y]es and [N]o to enable or disable the feature.
Use the [<][>] keys to scroll through the options.
Communications are enabled?
YES = The communications are enabled.
NO = The communications are disabled. No reporting codes will be transmitted to the
monitoring station. Note that downloading can still be accomplished with the
communicator disabled.
YES = The dialer will use DTMF dialing.
The PC4010 can switch to pulse dialing after a programmed number of attempts at
DTMF dialing have failed. See “DTMF Attempts”.
NO = The dialer will use pulse dialing.
Restore on Bell Time Out?
YES = The panel will send the restoral reporting code when both the zone is restored and the
bell has timed out (see “BELL CUTOFF” for the time the bell will time out). Note that if the
zone is not restored, the restoral will be sent when the partition is disarmed. DO NOT
enable this feature if “REST ON DISARM” is enabled.
NO = The panel will send the restoral reporting code when the zone is restored, or if “REST
ON DISARM” is enabled, the restoral is sent when the partition is disarmed. (See “REST
ON DISARM”.)
Restore on Disarming?
YES = The panel will send a restoral when the partition has been disarmed. The panel will not
send another alarm transmission for the zone until the partition is disarmed. DO NOT
enable “RESTORE ON BTO” if this feature is enabled. (See “RESTORE ON BTO”.)
NO = The panel will send the restoral immediately when the zone is restored, or if “RESTORE
ON BTO” is enabled, the restoral is sent when the bell times out. (See “RESTORE ON
BTO”.)
Note: If Bell Shutdown is to be used, do NOT use “Rest On Disarm” for Shutdown to occur.
Swinger Shutdown reset every 24 hours?
YES = The swinger shutdown counters will be reset everyday at midnight. The swinger
shutdown counters keep track of how many alarms have occurred on each zone before
entering shutdown, in which the zones will no longer cause an alarm. See “SWINGER
LIMIT” and “SWGR SHUT DOWN” to enable swinger shutdown.
NO = The swinger shutdown counters will be reset when the partition is armed.
Partial Closings Identified?
YES = The panel will identify all manually bypassed zones when the partition is armed. The
bypassed zones are identified by sending the zone alarm reporting codes for the
bypassed zones between the partial closing reporting code and the closing code. The
partial closing reporting code must be programmed for this feature to work.
See “MISC CLOSING” to program the partial closing reporting code.
See “PC ID RESTORES” to use zone restoral reporting codes instead of zone alarm
reporting codes to identify the bypassed zones.
NO = The panel will only send a partial closing reporting code to tell the monitoring station that
zones were bypassed when the partition was armed.
Partial Closings on Auto Arming?
YES = The panel will send the partial closing reporting code to the monitoring station when a
zone is force armed (temporarily bypassed) by an auto arm. If the option “PC ID” is
enabled, the force armed zone will be identified by sending its zone alarm reporting code
after the partial closing reporting code. See “FORCE ARM” for an explanation of force
arming.
NO = No partial closing reporting code will be sent when zones are force armed during auto arming.
COMMS TOGGLES
(1)
COMMS ENABLED
Y
DTMF DIALING
Y
RESTORE ON BTO
Y
REST ON DISARM
N
SHUT DOWN 24HRS
N
PC ID
N
PC ON AUTO ARM
Y