25
SYSTEM AREA
COMMUNICATOR
COMMS TOGGLES
Partial Closings Identified send Zone Restorals?
YES = The zone restoral reporting codes are transmitted to the monitoring station instead of the
zone alarm reporting codes to identify the manually bypassed zones and force armed
zones on auto arm. See “PC ID”.
NO = The zone alarm reporting codes are used to identify the bypassed zones.
Telephone Line Monitoring Enabled?
YES = The system tests for telephone line faults. If a fault is detected, the trouble is annunciated
on the keypads. A telephone line trouble is generated when the line voltage drops below 3
volts for more than 30 seconds.
NO = Does not test for Telephone Line faults.
Telephone Line Monitoring has Audible Bell Alarm?
YES = If there is a Telephone Line trouble and a partition is armed, the bell outputs for the armed
partition will be activated, along with the keypad annunciation. The bell outputs are any
outputs (Bell, SW Aux or PGM) programmed for “FIRE AND BURG”, “INV FIRE/ BURG”,
“BURG ONLY” and “INV BURG ONLY”.
NO = If there is a Telephone Line trouble, the panel will annunciate the trouble at the keypad
only.
Should a Failure to Communicate sound the Bells?
YES = If a partition is armed, the bell outputs for the armed partition will sound when the PC4010
fails to communicate with the monitoring station.
NO = A failure to communicate will not cause the PC4010 to sound the bells.
Should a Transmission Line Monitoring trouble and an alarm occurring cause the bells to sound?
YES = If a partition is armed, the bell outputs for the armed partition will sound when the PC4010
has both a TLM fault and an alarm occurring.
NO = The TLM and Alarm Audible Function is disabled.
Enable Ringback?
YES = The Ringback option is enabled.
A successful communication of a closing to the monitoring station will be annunciated by
the keypads beeping 5 times. Only the keypads belonging to that partition will beep.
Note: That if communications are being sent to more than one telephone number,
communications to all numbers will produce a ringback.
NO = The Ringback option is disabled.
Note: Ringback must be enabled on a commercial burglar alarm system.
Ringback Squawk?
YES = Ringback Squawk option is enabled.
NO = Ringback Squawk option is disabled.
If Ringback and Ringback Squawk are both enabled upon a successful communication of a
closing, the Fire/Burg, Inv Fire/Burg, Burg and Invert Burg outputs for that partition will squawk 4
times.
Note: Ringback must be enabled for this feature to function.
Periodic Test Transmission?
YES = The panel will send a test transmission to the monitoring station. See “TEST CODE TX” for
programming time and frequency the code is sent. See “SYSTEM MAINT” for programming
the reporting code.
NO = The panel will not send a test transmission.
European Dialing?
YES = When the communicator is pulse dialing, the contact closure to the phone line is made in a
67/33 make/break ratio. This is the European standard method of dialing.
NO = The contact closure to the phone line is made in a 60/40 make/break ratio. This is the
American/Canadian standard method of dialing.
PC ID RESTORES
N
TLM ENABLED
Y
TLM AUD BELL
Y
FTC AUD BELL
N
TLM + ALARM AUD
N
RINGBACK
N
RINGBACK SQUAWK
N
PERIODIC TX ?
N
EUROPE DIAL
N