26
SYSTEM AREA
COMMUNICATOR
COMMS TOGGLE S
/
COMM MIS C
Dial if No Dial Tone Present?
YES = If the first attempt by the panel to call the monitoring station fails, on every subsequent
attempt the panel will dial regardless of the presence of dial tone.
NO = If a ‘D’ for dial tone search precedes the phone number, the panel will not dial if dial
tone is not present. See “PGM TEL NUMBER” for programming the telephone numbers
with dial tone search.
Phone #2 back up Phone #1?
YES = The PC4010 will send the reporting code to the 2nd phone number if the 1st phone
number fails to communicate with the monitoring station after 10 attempts. Dialer
directions for the 2nd phone number should be disabled (set to “N”) if the 2nd number
is used for backup only, otherwise the reporting codes will be sent to the 2nd phone
number whether the 1st number failed or not.
NO = Disabled. The 2nd phone number does NOT back up the 1st phone number.
Phone #3 back up Phone #1?
YES = The PC4010 will send the reporting code to the 3rd phone number if the 1st phone
number fails to communicate with the monitoring station after 10 attempts. Dialer
directions for the 3rd phone number should be disabled (set to “N”) if the 3rd number is
used for backup only, otherwise the reporting codes will be sent to the 3rd phone
number whether the 1st number failed or not.
If “PH 1-2 BACKUP” is enabled when 1st phone number fails, the reporting code will be
sent to both the 2nd and 3rd phone number.
NO = Disabled. The 3rd phone number does NOT back up the 1st phone number.
Phone #3 back up Phone #2?
YES= The PC4010 will send the reporting code to the 3rd phone number if the 2nd phone
number fails to communicate with the monitoring station after 10 attempts. Dialer
directions for the 3rd phone number should be disabled (set to “N”) if the 3rd number
is used for backup only, otherwise the reporting codes will be sent to the 3rd phone
number whether the 2nd number failed or not.
If “PH 1-2 BACKUP” is enabled when 1st phone number fails, the reporting code will
be sent to the 2nd phone number. If the 2nd phone number fails, the reporting code
will then be sent to the 3rd phone number.
NO = Disabled. The 3rd phone number does NOT back up the 2nd phone number.
Busy Tone Detection?
Yes = If a busy tone is detected for 4 seconds the panel will hang-up and redial 60 seconds after
hearing the busy tone. By default this option is set to No.
No = The panel will not search for Busy Tone when dialing the phone number.
1300 Hz Identification Tone?
Yes = This Communications Toggle when enabled will allow the panel to emit a 1300Hz
Identification tone from the time the end of the phone number is dialed to the time that it
receives a handshake. By default this option is set to No.
No = No Identification tone will be transmitted when the panel dial out.
Note: This option must not be used with Pager 2, Pager 3 or Contact ID communications
formats.
Alternate Dialing?
Yes = This communications toggle option allows the panel to switch telephone number after a
failed communication attempt. If the panel is able to dial (force dialing not included) on
Phone Number One, but no handshake is received then the next communication attempt
will be to Phone Number 2 regardless of the dialer direction settings. This will cause the
panel to switch between phone number 1 and 2 until a handshake is received. If a
handshake is received but no kissoff is received from the receiver the panel will continue
to dial that phone number until the event FTC's or a phone number backup occurs. By
Default is option is set to No.
Note: When alternate dialing is enabled the control panel will ignore all dialer
directions and backup settings for phone number 2. Phone number 1 may be backed
up to phone number 3, however phone number 2 will not backup to phone number 3
with Alternate Dialing enabled.
No = The panel will not switch phone numbers if no handshake is received until the
programmed backup or dialer direction occurs.
DEFAULT DIAL
Y
PH 1-2 BACKUP
N
PH 1-3 BACKUP
N
PH 2-3 BACKUP
N
BUSY TONE DET
N
1300 HZ I.D.
N
ALTERNATE DIAL
N