23
YES = All other reporting codes are sent to the selected phone number
NO = All other codes are not sent.
“All other” refer to every other reporting code that is not an alarm or restoral, opening or closing.
“All other” groups of reporting codes are:
• System Maintenance Reporting Codes • 4400 Module Maintenance Reporting Codes
• 4204 Module Maintenance Reporting codes
See “Reporting Codes” for a description of these groups of reporting codes.
When a reporting code is sent to the monitoring station, a four digit account code is also sent to
identify the user. Each partition has its own account code (See “Customer ID Code”). But for
reporting codes that do not pertain to a particular partition, such as AC line trouble etc., the
system ID code is sent to identify the panel/user. The reporting code groups that send the
system ID code are:
• Module Tamper Alarms • System Maintenance Reporting Codes
• Module Tamper Restorals • 4204 Module Maintenance Reporting Codes
• 4400 Module Maintenance Reporting Codes • [F] [A] [P] Key Alarms (global keypads)
• Duress (global keypads) • [F] [A] [P] Key Restorals (global keypads)
• 4700 Reporting Codes
See “Reporting Codes” for a description of these groups of reporting codes.
See “Comms Formats” for a description of communication formats and if there are limitations set
on what the System and Partition account codes may be programmed as.
ALL OTHERS
Y
SYSTEM AREA
COMMUNICATOR
MAIN ITEMS
SYSTEM ID CODE
(3)