33
[1] Dial tone will add a 2 second search to the telephone number, which will be represented by
a letter “D” on the display. When the panel does a dial tone search, it looks for dial tone
before dialing the programmed phone number.
[2] Pause 2 Seconds will add a 2 second pause to the dialing sequence, which will be
represented by the letter “E” on the display.
[3] Pause 4 Seconds will add a 4 second pause to the dialing sequence, which will be
represented by the letter ‘A‘ on the display.
[4] DTMF [Q] will input an asterisk, represented by a ‘B‘ on the display. The dialer will output the
same frequencies as a touch tone phone would if the [Q] key were pressed. (Frequency
required to disable call waiting.)
[5] DTMF [#] will add a ‘#’ represented by a ‘C’ on the display. The dialer will output the same
frequencies as a touch tone phone would if the [#] key were pressed.
This section contains all options related to the use of the Links module.
Links Module?
YES = Links module enabled. This selection must be enabled in order for the Links unit to
operate.
NO = Links module disabled.
Note: Once the Links module is selected the Main PGM OUT automatically changes to Links
Operation and cannot be reprogrammed until the Links module is deactivated.
Links Test Transmission?
YES = A test transmission is sent by the panel for the Links unit. (See ‘Tx Cycle Days’ and ‘Tx
Cycle Time’.)
NO = No test transmission is sent by the panel for the Links unit.
Note: The Links Test Transmission Code can be programmed under system maintenance of
the reporting code section.
Zone 1 Links Supervisory?
YES = Zone 1 Links Supervisory enabled. This zone is used to indicate the trouble conditions of
the Links unit. The troubles are: Loss of Cellular Communications, AC, DC and Tamper.
Notes: Cellular trouble reporting codes are programmed as Zone Trouble and Restoral. For
clear identification of the Cellular Trouble, program a zone label that will identify the zone
as Links zone.
If Partial Closings identify alarms are used the Alarm Reporting Code must be programmed
for the feature to function properly.
EOL resistors must be used for the Links Supervisory zone (see System Toggle Options).
Do NOT use the double EOL resistor on the Links Supervisory zone.
NO = Zone 1 Links Supervisory disabled
Note: When this option is enabled the PC4010 will automatically reprogram the zone type
and options to be Links Supervisory for zone 1. The zone type cannot be changed until this
option is disabled.
Zone 2 Links Answer?
YES = Zone 2 Links Answer enabled. This zone is used when downloading is to be performed
through the Links unit.
Note: EOL resistors must not be used on the Links Answer zones.
NO = Zone 2 Links Answer disabled.
Note: When this option is enabled the PC4010 will automatically reprogram the zone type and
options to be Links Answer for zone 2. The zone type cannot be changed until this option is
disabled.
Enter the number of days between test code communications. Valid entries are from 001 to 255. The
default setting is 030.
Enter the time of day the test code will be communicated. Times are entered using military format
HH:MM. The default setting is 0000.
LINKS TOGGLES
(4)
LINKS MODULE
N
PERIODIC TX
N
ZONE 1 SUP
N
ZONE 2 ANSWER
N
TX CYCLE DAYS
(5)
TX CYCLE TIME
(6)