43
If the reporting code is left as default FF, the RC (reporting code) will be the same as the zone
number and the FB (function byte) for the zone events will be chosen form the corresponding
zone type. A zone has 7 associated events that will modify the printer MSG:
PC4010 Event DVAC Printer MSG
Zone Alarm Alm
Zone Restore Rst
Partial Closing+ Zone Alarm Byp
Zone Trouble/Tamper Trb
Zone Trouble/Tamper Restore T_R
Zone Fault Sup
Zone Fault Restore S_R
The following is a list of the default settings for zone transmissions:
Zone Type FB: Alm Rst Byp Trb T_R Sup S_R Printer MSG
Standard Delay 08 88 48 28 A8 68 E8 Delay
Aux. Delay 08 88 48 28 A8 68 E8 Delay
Instant 09 89 49 29 A9 69 E9 Instant
Interior 0A 8A 4A 2A AA 6A EA Interior
Interior H.A 0B 8B 4B 2B AB 6B EB InteriHA
Delay H.A 07 87 47 27 A7 67 E7 DelayHA
24 hr Bell 11 91 51 31 B1 71 F1 24 hr
24 hr Bell/Buzzer 11 91 51 31 B1 71 F1 24 hr
24 hr Buzzer 11 91 51 31 B1 71 F1 24 hr
Standard Fire 00 80 40 20 A0 60 E0 Fire
Delayed Fire 00 80 40 20 A0 60 E0 Fire
Auto Ver. Fire 00 80 40 20 A0 60 E0 Fire
Momentary Arm XX
Maintained Arm XX
Latching 24 hr 16 96 56 36 B6 76 F6 24hrLat
Forced Answer XX
Links Supervisory 18 98 58 38 B8 78 F8 Supervi
Links Answer XX
Sprinkler 01 81 41 21 A1 61 E1 Sprnklr
Hold Up 03 83 43 23 A3 63 E3 Hold Up
Panic 02 82 42 22 A2 62 E2 Panic
Technical 18 98 58 38 B8 78 F8 Supervi
Enter this section to restore the PC4400 programming back to the default values.
Note: When exiting installers mode, if the panel loses communications with the PC4400
module, the message “DVAC module not present” will be displayed. If this occurs check
your wiring, then enter and exit installers mode again.
DEFAULT DVAC