59
This section will determine if the location of a zone is good. Once this section has been entered
the panel will then prompt the installer to select a zone to be tested. Use the [<][>] keys to scroll
to the desired zone. Then press the [Q] key to select the zone. The keypad will now display the
message “Please Activate Zone”. When this message is displayed open then close the zone from
the intended mounting location. The keypad will display the result of the module placement test
(with respect to RF strength). Placement results are as follows:
Good - This result will be displayed on the keypad as ***good*** and the keypad will beep once
indicating that the placement was good. A placement result of good means that the zone is
placed in a location that has a strong RF transmission strength.
Fair - This result will be displayed on the keypad as ***fair*** and the keypad will beep twice
indicating that the placement was fair. A placement result of fair means that the zone is placed in
a location that has passed the module placement test.
Poor - This result will be displayed on the keypad as ***poor*** and the keypad will beep three
times, indicating that the placement was poor. A placement result of poor means that the zone is
placed in a location that has weak RF transmission strength and should be relocated. In most
cases it should only be necessary to move the zone a short distance from its original intended
location. After relocating the zone repeat the module placement test. When the test results are
satisfactory, continue with the next zone to be tested.
Note: To perform a module placement test on an RF PIR motion detector, the zone must be
tampered then restored instead of opened then closed.
Once this selected has been made the LCD will display the message “Confirm Default Press Q”. To
abort press any other key. Once the [Q] key has been pressed the LCD will display the message
“Resetting “. All RF zone signatures will have been erased from the PC4164. Note: Deleting the RF
signatures from the PC4164 will not remove the zone(s) from the partition assignment(s).
MODULE HARDWARE
RF ZONE OPTIONS
PLACEMENT TEST
(3)
DEFAULT SRL #’S
(4)