SYSTEM AREA
EVENT MESSAGES
ZONE TAMPER
(6)
ZONE FAULT
(7)
SENSOR RESET
(4)
UTILITY OUTPUT
(5)
This message will be displayed for the sensor reset option in the [Q] menu. This message will
also be displayed when a sensor reset is performed.
This message will be displayed for the utility output option in the [Q] menu. This message will also
be displayed when a utility output is performed.
Notes: Since editing this label will affect how the Utility Output and Sensor Reset labels appear on all partitions if
the outputs perform different functions on different partitions the labels should be left at default.
The logs to the viewable and printed event buffer will not use the programmable label. They will continue to log as
“Utility Output” and “Sensor Reset”.
The “Zone Tamper” message will appear on every partition keypad when a zone using double EOL
is put into the tamper condition (zone open). The message is displayed while viewing open zones.
The “Zone Fault” message will appear on every partition keypad when a zone using double EOL is
put into the fault condition (zone shorted). The message is displayed while viewing open zones.
Note: Zone Tamper and Zone Fault sections will only appear when double EOL is being used.

Other manuals for DSC MAXSYS PC4010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4010 and is the answer not in the manual?

DSC MAXSYS PC4010 Specifications

General IconGeneral
BrandDSC
ModelMAXSYS PC4010
CategorySecurity System
LanguageEnglish

Related product manuals