2009 DURATECH TUB GRINDER OPERATING INSTRUCTIONS
3. Output 10 on the reciever is energized when any of functions 3‑8 are pressed.
4. Functions 1 & 2 are interlocked latched functions and are used for tub rotation. Pressing one function
will start that function. It will not stop until either button is pressed. There is a two second delay when
changing tub direction.
5. Functions 3‑8 are interlocked momentary functions. These are used for hydraulic cylinder functions.
These functions are energized only when the buttons are pressed. Functions 3 & 4 are used for conveyor
lift. Functions 5,6,7, and 8 can be used with the Tub Cover option.
For more information on using and troubleshooting the Omnex Origa system, please refer to Section 6.4,
“Troubleshooting the Omnex Wireless Remote Controls” or Section 6.5 for “Trouble Shooting Omnex Wireless 10
Button Remote Control”.
Remote radio start up
To begin using the remote radio, perform the following steps:
1. Press the green (power on) button on the transmitter. The yellow LED should start ashing to indicate
that the transmitter is transmitting.
2. Set tub rotation to neutral on the machine’s control panel.
3. Press the Radio start switch on the control panel and hold it in.
4. Set the radio switch on the control panel to “REMOTE”.
5. Count to 5 and release the Radio start switch.
Radio shutdown (switching back to local)
1. Set the radio switch on the control panel to “LOCAL”.
2. Press red button on the transmitter, and set the in the storage location on the control panel. Transmitter
batteries will run down if transmitter is not turned off.

Table of Contents