7 Recommended Maintenance
The actions in Table 16 should be performed routinely.
WARNING: When performing any GSC400 or Engine
maintenance be certain controller is in OFF Mode,
is isolated from all possible sources of power, and
the Crank wire is removed from the Controller.
Table 16 – Recommended Maintenance
Procedure Action
Making the controller safe for inspection and
maintenance.
Disconnect all possible power sources before
controller inspection.
Inspect controller mounting location for
possible safety issues
Inspect mounting location for any safety or fire
issues. Inspect for dirt, wiring damage and
mechanical damages.
Inspect controller for loose fasteners, terminals
and wiring connections.
Check all hardware including controller wiring,
terminals etc. for any looseness due to
vibrations etc.
Clean area around controller Periodically inspect and remove any debris/dirt
from within or near the controller.
Check for any overheating due to loose
connections
Check for any discoloration, melting or
blistering of any wiring or connections
Perform regular testing of controller Perform regular testing of the controller to
check for proper operation.

Table of Contents

Other manuals for DynaGen GSC400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DynaGen GSC400 Series and is the answer not in the manual?

DynaGen GSC400 Series Specifications

General IconGeneral
BrandDynaGen
ModelGSC400 Series
CategoryController
LanguageEnglish

Related product manuals