P.85
CAUTION When the lubrication oil level exceeds the upper limit, the oil may leak to
the pump side. Thus, be sure no to exceed the upper limit line when
adding the oil.
CAUTION When the lubrication oil level is lower than the lower limit line, serious
failure may be caused. If you find out the shortage, add the oil
immediately.
7.5 Spare (Maintenance) Parts List
Following parts are needed for maintenance in customers' site.
Table. 7.2 Spare (Maintenance) Parts List
1. Standard consumption Part.
2. Recommendable Spare Parts (Not needed for each pump.)
N2 gas pressure regulator *
* for MODEL EV-S**P / MODEL EV-S**N
Following labels are attached to pump covers. When they are hard to read for
discoloring or peeling off, please stick them again as directed.
Table 7.3 Labels
[DANGER] HAZARDOUS WAIGHT DANGER LABEL
C-7110-316-0001
[WARNING] HAZARDOUS VOLTAGE WARNING LABEL
C-7110-313-0001
[WARNING] HIGH TEMPERATURE WARNING LABEL
C-7110-312-0001
[WARNING] HAZARDOUS MATERIAL WARNING LABEL
C-7110-314-0001
[CAUTION] CHARGE MARK LABEL
C-7110-155-0001
PM10U
EBARA