P.80
7.2 Routine Inspection
Check periodically that ALARM signal is not output on the LCD controller or
remote output.
Table 7.1 Typical check items
No. Item How to check
Interval
(recommended)
Motor Power
LCD
1 time/week
2
N
2
Gas Flow(EV-S**P / EV-S**P)
LCD
3
Vibration / Noise
-----
4
Cooling water flow
LCD
5
Pump casing Temp.
LCD
6
Color of lubricating oil
Visual
1 time/month
When the WARNING/ALARM display appears, take action in accordance with
Section 11. "Troubleshooting."
If the lubrication oil amount is lower than the lower limit line of the oil level gauge,
supply the lubrication oil. See the section 7.4 Lubrication oilwhen adding the
oil.
WARNING Switch off the power supply to the pump first and interrupt the
Circuit Protector (CP) and lockout before you start on
maintenance.
WARNING The pump and exhaust piping will remain at a high temperature
during operation and for a short time after the pump has
stopped.
Be sure to avoid contact and keep inflammable substances out
of reach.
Do not remove the outer cover during operation.
Even when the cause of the WARNING/ALARM signal has been removed the
signal will be maintained until the RESET signal is entered. After you have taken
the remedial action, press the RESET button on the controller or enter the RESET
signal from the control signal connector to reset the WARNING.