10.3 Troubleshooting (3) ALARM
Display
Symptom
Check Item
Corrective Action
ALARM: WATER
FLOW LOW
Water flow is reduced.
Coupler is disconnected.
Connect coupler.
Pressure is not sufficient.
Apply sufficient pressure.
Root valve is closed.
Open valve.
Water pipe is clogged.
Clean or replace piping.
Tube fittings are loosened.
Re-tighten.
Instrument failure
Replace instrument.
Outlet & inlet pipes are
reverse. (flow value 0
L/min)
Connect pipes correctly.
ALARM: CASING
TEMP H.HIGH
Pump casing temp.
rises.
Pump back press. rises.
Check exhaust pipe.
Increase of the gas load.
Reduce the inflow gas amount.
Cooling water flow is
reduced.
Cool pump thoroughly and
reset.
Accumulation of
by-products
Replace or overhaul pump.
ALARM:BP MOTOR
TEMP H.HIGH
ALARM:MP MOTOR
TEMP H.HIGH
Booster Pump (BP)
motor coil temp. rises.
Main Pump (MP)
motor coil temp. rises.
Cooling water flow is
reduced.
Cool pump thoroughly and
reset.
Motor failure
Replace or overhaul pump.
ALARM:BP MOTOR
OVERLOAD 2
ALARM:MP MOTOR
OVERLOAD 2
BP motor current
rises.
MP motor current
rises.
Pump back press. rises.
Check exhaust pipe & silencer.
Increase of the gas load.
Reduce the inflow gas amount.
Rotor makes contact.
(Accumulation of
by-products)
(Substance plunge)
Replace or overhaul pump.
Instrument failure
Replace instrument.
ALARM:BP MOTOR
STEP OUT
ALARM:MP MOTOR
STEP OUT
Booster Pump (BP)
motor step out.
Main Pump (MP)
motor step out.
Can not restart.
Pump back press. rises.
Check exhaust pipe.
Increase of the gas load.
Reduce the inflow gas amount.
Rotor makes contact.
(Accumulation of
by-products)
(Substance plunge)
Replace or overhaul pump.
Instrument failure
Replace instrument.
ALARM:
BP DRIVER ###
ALARM:
MP DRIVER ###
BP Motor driver
protection
MP Motor driver
protection
Can not restart
Pump back press. rises.
Check exhaust pipe.
Increase of the gas load.
Reduce the inflow gas amount.
Rotor makes contact.
(Accumulation of
by-products)
(Substance plunge)
Replace or overhaul pump.
Cooling water flow rate is
reduced.
Cool pump thoroughly and
reset.
Motor driver has broken
down.
Replace motor driver.
ALARM:
PHASE ERROR
Open phase
Instrument failure
Replace instrument.
Incorrect wiring
Check power supply
ALARM:STARTFAIL
ALARM/WARN EXIST
Start fault
Starting during
WARNING/ALARM status
Make sure that all starting
conditions are met.
Instrument failure
Replace instrument.
After you have taken the remedial actions above, reset the pump. If the problem that has caused the