PM10U
EBARA
CORPORATION
“MODEL EV-A10”
in this instruction manual is our model code.
ISSUED BY PRECISION MACHINERY COMPANY
INSTRUCTION MANUAL
MULTI-STAGE DRY VACUUM PUMP
MODEL EV-A10
STANDARD MODEL
200-240V (1Phase 50/60Hz)
200-240V (3Phase 50/60Hz)
CAUTION
Read and understand this INSTRUCTION MANUAL thoroughly before using
this equipment.
Be sure to keep this INSTRUCTION MANUAL on hand for future reference.
To Facility and Tool Manufactures:
Be sure to distribute this INSTRUCTION MANUAL to all end-user personal
actually operation this equipment.
EVA_STD_E_Rev.3

Questions and Answers

  • C
    Casey MillerAug 15, 2025
    What to do if the EBARA Water Pump circuit protector is activated?
    • J
      James DickersonAug 15, 2025
      If the circuit protector is activated, it could be due to incorrect wiring, in which case you should check the wiring. Alternatively, it might be due to a short circuit, requiring you to replace or overhaul the pump.
  • S
    Stephen PerryAug 18, 2025
    What to do if my EBARA EV-A10 Water Pump is making abnormal noise and excessive vibration?
    • T
      Travis RussellAug 18, 2025
      Abnormal noise and excessive vibration in your EBARA water pump can occur if the adjustment feet are not applied; use the adjustment feet. It may also happen if some object is making contact with the outer cover, so remove the object. Another cause is that the fastening screws of the outer cover have worked themselves loose; tighten the fastening screws. In some cases, parts of the pump are damaged, requiring you to replace or overhaul the pump.
  • M
    Mrs. Kristin TaylorAug 21, 2025
    Why does the display appear and ALM lamp light on my EBARA EV-A10 Water Pump?
    • S
      sgonzalezAug 21, 2025
      The display and ALM lamp lighting up on your EBARA water pump can indicate an inverter overheat. In this case, you should cool down the inverter.
  • J
    jharrisAug 25, 2025
    What to do if my EBARA EV-A10 rotation speed does not increase?
    • P
      Patricia OlsonAug 25, 2025
      If the rotation speed of your EBARA water pump does not increase, it could be due to several reasons. The pump might be overloaded, so check the pressure and exhaust pipe. There could be a frequency order failure, requiring you to tune the instruments up. Parts of the pump could be damaged, meaning you should replace or overhaul the pump. Also, check the power supply, as a supplied voltage failure could be the cause.
  • O
    ofrancoAug 27, 2025
    What to do if my EBARA Water Pump does not start when applying START button?
    • K
      Katherine SosaAug 27, 2025
      If your EBARA water pump does not start when you press the start button, ensure that the switch is not set to “Remote” mode; instead, set it to “Local” mode. Also, verify that all start-up conditions are satisfied. Finally, instrument failure can also cause this issue, so consider replacing the instruments.
  • R
    Robert EdwardsAug 30, 2025
    What to do if my EBARA EV-A10 Water Pump display appears and ALM lamp lights?
    • A
      Adam MaysAug 30, 2025
      If the display appears and the ALM lamp lights up, it could be due to insufficient supplied voltage, incorrect wiring, or a momentary power failure. Input regular voltage, check the wiring, and check the power supply. It could also be due to instrument failure, so replace instruments.
  • A
    Angelica McdonaldSep 2, 2025
    What to do if nothing appears on the operation panel of my EBARA Water Pump?
    • L
      Linda GonzalesSep 2, 2025
      If nothing appears on the operation panel of your EBARA water pump, first check the power supply to the pump. Also, ensure that the CP is turned ON. If there is no wiring of power supply, connect the power connector. Finally, instrument failure may be the cause, so replace instruments.
  • C
    cmooreSep 5, 2025
    What to do if my EBARA EV-A10 Water Pump does not start when entering external “RUN” signal input?
    • J
      jenniferparrishSep 5, 2025
      If your EBARA water pump does not start when entering an external “RUN” signal, make sure the switch is set to “Remote” mode, not “Local”. Also, ensure that all start-up conditions are satisfied. If the problem persists, the instrument may be failing, and you should replace it.
  • R
    romeroashleySep 8, 2025
    Why does my EBARA Water Pump start suddenly?
    • J
      James HenrySep 8, 2025
      If your EBARA water pump starts suddenly, it is possible that the “RUN” signal was input before the CP was turned ON. To resolve this, interrupt the “RUN” signal before supplying power.
  • J
    John NewmanSep 12, 2025
    Why is vacuum pressure increasing in my EBARA EV-A10?
    • H
      Hayley CastroSep 12, 2025
      If the vacuum pressure is increasing in your EBARA water pump, it could be due to a leak from the vacuum piping. Check the piping to resolve this issue.

Summary

Environmental Basic Policies

Forword

Warranties

General Warranty Limitations and Exclusions

Details limitations and exclusions for product warranties.

Safety Notice

Safety Warning Labels

High temperature warning

Warning about hot surfaces and contact precautions.

Hazardous voltage warning

Warning about electrical shock and safety measures.

Hazardous weight danger

Danger from heavy objects, tipping, or falling.

Electric charge mark

Symbol indicating electric charge.

Environmental Concerns

Acceptance Check

Product Description

Outline

Overview of the pump's compact design and suitability for clean gases.

Control System

Built-in measuring unit including CP, Noise Filter, and Inverter.

The Way of Pump Moving

Procedures and precautions for safely moving the pump.

Detailed Specifications

Model Description

Explanation of model naming conventions and specifications.

Specifications

Key technical specifications of the EV-A10 pump.

Outline Drawing

Visual representation of the pump's dimensions and component layout.

Performance Curve

Graph showing pump performance characteristics.

System Flow

Diagrams illustrating the pump's operational system flow.

Installation

Location

Guidelines for selecting an appropriate installation site and conditions.

Piping

Instructions for connecting vacuum and exhaust piping.

Electrical Wiring

Detailed procedures for power supply and control signal wiring.

Operation

Before Starting

Pre-operational checks and power-on procedures.

START; STOP

Procedures for starting and stopping the pump in Local/Remote modes.

Operation when momentarily power failure happens

How the pump behaves during temporary power interruptions.

Gas Ballast

Information on using the gas ballast feature.

Maintenance and Inspection

Routine Inspection

Periodic checks for alarms and abnormal symptoms.

Vacuum and Exhaust Piping

Maintenance procedures for vacuum and exhaust piping.

Repair and Service

Storage; Disposal

Disconnection and Transportation

Troubleshooting

Basic trouble

Common problems and their corrective actions.

EBARA EV-A10 Specifications

General IconGeneral
ModelEV-A10
CategoryWater Pump
Maximum Working Pressure10 bar
Frequency50 Hz
Protection DegreeIP55
ApplicationWater supply, irrigation, industrial
MaterialStainless Steel
ImpellerStainless Steel
Liquid TemperatureUp to 60°C
Outlet1 inch
Voltage230 V