CAUTION Do not stack the pump. Pump must be placed in an upright
position. When the pump is overturned, lubricating oil inside a
pump may leak to a rotor room, and it may cause trouble to
operation.
2.2 Environmental Concerns
Handling or operating the unit other than specified may induce adverse impacts on the
environment. Follow the descriptions below to handle, operate, and maintain the unit.
(1) Ask an authorized waste-disposal company to dispose packing materials from
uncrating according to laws and ordinances applicable to the waste.
(2) Failure to do the unit maintenance (including overhaul) may trigger accidents causing
injury or death, unit troubles, or environmental pollution. Plan the maintenance and
perform it periodically to operate the unit efficiently.
(3) To dispose the unit, follow effective laws and ordinances applicable in the area where
the unit is installed.
(4) To dispose the lubricant oil and chemicals, follow effective laws and ordinances
applicable in the area where the unit is installed.
WARNING If the pump becomes damaged during shipment or if parts are missing,
immediately contact EBARA. If a leaking or damaged product is used,
an accident resulting in injury or death could occur or the product
could become further damaged. Even if leakage occurs, take
measures to ensure they will not be directly discharged from the site,
as such leakage also wastes resources.
CAUTION If the product is not to be immediately installed, store it in a clean, dry
location.