Manual shutdown Manual control switch input D31/D32
on OFF
-, 0..
99
0
Hardware fault The internal hardware has a fault
Priority is applicable for the messages
EEPROM fault, RTC fault, Flash fault
-, 0..
99
1
Sollwertverst. Message is generated during setpoint
adjustment
0..99 0
Refrig.Pt.Dis. Cooling interrupted by VS via CAN bus -, 0..
99
0
Battery voltage Low battery voltage -, 0..
99
0
Safety chain Safety chain -, 0..
99
1
Verdichter Endt. Compressor end temperature -, 0..
99
0
Menu 6-6 - Emergency power operation
NOTNETZPOS: XXXXX Input Default
Fkt. Kühl. AUS xxx Cooling functionality switched off during emergency power operation? (Y/N)
, , (Y/N)
N
Fkt. Abt. AUS xxx Defrost functionality switched off during emergency power operation? (Y/N)
, , (Y/N)
N
Fkt. Lüft. AUS xxx Fans functionality switched off during emergency power operation? (Y/N)
, , (Y/N)
N
Fkt. Rhmhg.AUS xxx Frame heater functionality switched off during emergency power operation? (Y/N)
, , (Y/N)
N
Fkt. Licht AUS xxx Light functionality switched off during the emergency power operation? (Y/N)
, , (Y/N)
N
9.2 Controller type SPIR290 - Menu tree
DIP switch S3 SPIR290
1: OFF
2: ON
3: OFF
4: ON/OFF = Master / Slave mode ON/OFF
5..8: OFF
9: ON
Submenu Submenu 2 Menu number Menu name
Main menu 0 REFRIGERATION POINT
Actual values 1 ACTUAL VALUES