Summary

System Design of UA 300 D

Interfaces

Describes communication interfaces like CAN bus, Display, TTY.

Digital Inputs and Outputs

Details digital inputs and relay/transistor outputs for the controller.

Analog Inputs

Describes analog inputs for temperature sensors.

Real-time Clock Functionality

Mentions battery-backed real-time clock for stand-alone operation.

Application of UA 300 D

Controller Versions

Lists different versions of the UA 300 D Case Controller.

Controller Types Explained

Details the three main controller types: UA 111 X, UA 111 XP, UR 141.

Version Update Procedures

Explains the process and implications of updating the controller EPROM.

Function of UA 300 D

3.1 Selecting Sensor Type

Explains how to select and use different temperature sensor types.

3.1.1 Required and Optional Sensors

Lists sensor requirements based on controller type and operating mode.

3.2 Controller Function

Describes various control functions based on controller type.

3.2.1 Cooling (Solenoid Valve)

Details how cooling is controlled via solenoid valve for different controller types.

3.2.2 Compressor Control

Explains various compressor control strategies and parameters.

3.2.3 Defrosting

Explains defrosting methods (off-cycle, heating) for different controller types.

3.2.4 Fan Control with Case Controllers

Details fan control in multidecks for UA 111 X/XP.

3.2.5 Fan Control with Coldroom Controllers

Describes fan control for UR 141 in LT coldrooms.

3.2.6 Door Contact

How coldroom door contacts affect cooling and fan operation.

3.2.8 Setpoint Toggle (Day;Night Operation)

Switching between standard and alternative setpoints.

3.2.10 Archiving Operating Data

How operating data, including temperature, is recorded and stored.

3.2.12 Clock

Internal clock functions, including daylight saving and battery backup.

Installation and Startup of UA 300 D

4.1 Connection and Safety Notes

Essential safety precautions and connection guidelines for installation.

4.2 Installation

General overview of controller installation methods.

4.2.1 UA 300 D xC DIN Rail Mounting

Specific instructions for mounting the UA 300 D xC on DIN rails.

4.2.2 UA 300 D xS Control Panel Mounting

Instructions for panel mounting the UA 300 D xS controller.

4.3 Basic Parameter Settings

Steps for initial hardware and software parameter configuration.

4.3.1 Setting the CAN Bus Address

How to set Node No. or CAN bus address using decade switches.

4.3.2 Setting the Controller Type

Selecting the controller type (UA 111 X, XP, UR 141) via DIP switch.

4.3.3 First Start - Loading Basic Settings

Procedure for initial controller startup and loading default settings.

4.4 Maintenance and Battery Replacement

Guidelines for maintaining the controller and replacing the backup battery.

4.4.1 Replacing Battery on UA 300 D xC

Step-by-step guide for replacing the battery in the xC version.

4.4.2 Replacing Battery on UA 300 D xS

Step-by-step guide for replacing the battery in the xS version.

Pin and Terminal Assignments of UA 300 D

Digital Inputs 230 V AC

Lists digital input assignments for different controller types.

Sensors

Details sensor terminal assignments for case and coldroom controllers.

Relay Outputs 230 V AC

Lists relay output assignments and their functions.

5.1 UA 300 D xC as Case Controller

Pin assignments for UA 300 D xC as a case controller.

5.2 UA 300 D xC as Coldroom Controller

Pin assignments for UA 300 D xC as a coldroom controller.

5.3 UA 300 D xS as Case Controller

Pin assignments for UA 300 D xS as a case controller.

5.4 UA 300 D xS as Coldroom Controller

Pin assignments for UA 300 D xS as a coldroom controller.

Operation of UA 300 D

6.1 Operation with CI 3000 Store Computer; AL 300 Operator Terminal

Details operation using CI 3000 or AL 300 terminals.

6.2 Menus and Screens

Explains the menu structure and screen navigation for the controller.

6.2.1 Remote Operation;Parameter Setting of Case;Coldroom Controller

Setting parameters remotely via CI 3000 or AL 300 terminals.

6.3 Entering Refrigeration Point Parameters

Steps to name and configure refrigeration points.

6.4 Operation with BT 300 x Operator Interface

Operating the controller using the BT 300 x interface.

6.4.1 Defining the Refrigeration Point

Parameters for defining a refrigeration point (name, ID, priority, etc.).

6.4.2 Defining the Controller

Selecting the controller type and its implications.

Menu Structure UA 300 D

7.1 Controller type UA 111 X - Menu Tree

Detailed breakdown of menus and screens for UA 111 X.

7.2 Controller type UA 111 XP - Menu Tree

Detailed breakdown of menus and screens for UA 111 XP.

7.3 Controller type UR 141 - Menu Tree

Detailed breakdown of menus and screens for UR 141.

Alarms and Messages of UA 300 D

Hardware Faults

Lists and explains hardware-related faults and their corrections.

Messages

Lists system messages, their causes, and corrections.

8.1 Alarms

Details specific alarm conditions like door open, temperature, and defrost.

8.3 Transient Alarms and Messages

Describes one-time event alarms that require manual cancellation.

Specifications of UA 300 D

9.1 Electrical Data

Provides detailed electrical specifications for different controller versions.

9.2 Mechanical Data

Includes mechanical dimensions and mounting details.

9.2.1 DIN Rail Mounting of UA 300 D xC

Technical drawings for DIN rail mounting.

9.2.2 Panelmounting of UA 300 D xS

Technical drawings for panel mounting.

Summary

System Design of UA 300 D

Interfaces

Describes communication interfaces like CAN bus, Display, TTY.

Digital Inputs and Outputs

Details digital inputs and relay/transistor outputs for the controller.

Analog Inputs

Describes analog inputs for temperature sensors.

Real-time Clock Functionality

Mentions battery-backed real-time clock for stand-alone operation.

Application of UA 300 D

Controller Versions

Lists different versions of the UA 300 D Case Controller.

Controller Types Explained

Details the three main controller types: UA 111 X, UA 111 XP, UR 141.

Version Update Procedures

Explains the process and implications of updating the controller EPROM.

Function of UA 300 D

3.1 Selecting Sensor Type

Explains how to select and use different temperature sensor types.

3.1.1 Required and Optional Sensors

Lists sensor requirements based on controller type and operating mode.

3.2 Controller Function

Describes various control functions based on controller type.

3.2.1 Cooling (Solenoid Valve)

Details how cooling is controlled via solenoid valve for different controller types.

3.2.2 Compressor Control

Explains various compressor control strategies and parameters.

3.2.3 Defrosting

Explains defrosting methods (off-cycle, heating) for different controller types.

3.2.4 Fan Control with Case Controllers

Details fan control in multidecks for UA 111 X/XP.

3.2.5 Fan Control with Coldroom Controllers

Describes fan control for UR 141 in LT coldrooms.

3.2.6 Door Contact

How coldroom door contacts affect cooling and fan operation.

3.2.8 Setpoint Toggle (Day;Night Operation)

Switching between standard and alternative setpoints.

3.2.10 Archiving Operating Data

How operating data, including temperature, is recorded and stored.

3.2.12 Clock

Internal clock functions, including daylight saving and battery backup.

Installation and Startup of UA 300 D

4.1 Connection and Safety Notes

Essential safety precautions and connection guidelines for installation.

4.2 Installation

General overview of controller installation methods.

4.2.1 UA 300 D xC DIN Rail Mounting

Specific instructions for mounting the UA 300 D xC on DIN rails.

4.2.2 UA 300 D xS Control Panel Mounting

Instructions for panel mounting the UA 300 D xS controller.

4.3 Basic Parameter Settings

Steps for initial hardware and software parameter configuration.

4.3.1 Setting the CAN Bus Address

How to set Node No. or CAN bus address using decade switches.

4.3.2 Setting the Controller Type

Selecting the controller type (UA 111 X, XP, UR 141) via DIP switch.

4.3.3 First Start - Loading Basic Settings

Procedure for initial controller startup and loading default settings.

4.4 Maintenance and Battery Replacement

Guidelines for maintaining the controller and replacing the backup battery.

4.4.1 Replacing Battery on UA 300 D xC

Step-by-step guide for replacing the battery in the xC version.

4.4.2 Replacing Battery on UA 300 D xS

Step-by-step guide for replacing the battery in the xS version.

Pin and Terminal Assignments of UA 300 D

Digital Inputs 230 V AC

Lists digital input assignments for different controller types.

Sensors

Details sensor terminal assignments for case and coldroom controllers.

Relay Outputs 230 V AC

Lists relay output assignments and their functions.

5.1 UA 300 D xC as Case Controller

Pin assignments for UA 300 D xC as a case controller.

5.2 UA 300 D xC as Coldroom Controller

Pin assignments for UA 300 D xC as a coldroom controller.

5.3 UA 300 D xS as Case Controller

Pin assignments for UA 300 D xS as a case controller.

5.4 UA 300 D xS as Coldroom Controller

Pin assignments for UA 300 D xS as a coldroom controller.

Operation of UA 300 D

6.1 Operation with CI 3000 Store Computer; AL 300 Operator Terminal

Details operation using CI 3000 or AL 300 terminals.

6.2 Menus and Screens

Explains the menu structure and screen navigation for the controller.

6.2.1 Remote Operation;Parameter Setting of Case;Coldroom Controller

Setting parameters remotely via CI 3000 or AL 300 terminals.

6.3 Entering Refrigeration Point Parameters

Steps to name and configure refrigeration points.

6.4 Operation with BT 300 x Operator Interface

Operating the controller using the BT 300 x interface.

6.4.1 Defining the Refrigeration Point

Parameters for defining a refrigeration point (name, ID, priority, etc.).

6.4.2 Defining the Controller

Selecting the controller type and its implications.

Menu Structure UA 300 D

7.1 Controller type UA 111 X - Menu Tree

Detailed breakdown of menus and screens for UA 111 X.

7.2 Controller type UA 111 XP - Menu Tree

Detailed breakdown of menus and screens for UA 111 XP.

7.3 Controller type UR 141 - Menu Tree

Detailed breakdown of menus and screens for UR 141.

Alarms and Messages of UA 300 D

Hardware Faults

Lists and explains hardware-related faults and their corrections.

Messages

Lists system messages, their causes, and corrections.

8.1 Alarms

Details specific alarm conditions like door open, temperature, and defrost.

8.3 Transient Alarms and Messages

Describes one-time event alarms that require manual cancellation.

Specifications of UA 300 D

9.1 Electrical Data

Provides detailed electrical specifications for different controller versions.

9.2 Mechanical Data

Includes mechanical dimensions and mounting details.

9.2.1 DIN Rail Mounting of UA 300 D xC

Technical drawings for DIN rail mounting.

9.2.2 Panelmounting of UA 300 D xS

Technical drawings for panel mounting.

ECKELMANN UA 300 D Specifications

General IconGeneral
Power Supply24 V DC
DisplayLCD
Input voltage24 V DC
Number of digital inputs8
Number of analog inputs4
Protection classIP20
InputsDigital, Analog
OutputsDigital, Analog
CommunicationRS-485