9 Operating faults / Trouble shooting
Fault
Possible cause
Rectification
Metering pump does not
work, green LED not
showing
Incorrect voltage
Check power supply
Pump does not suck up
despite bleeding and max.
stroke setting
deposits, adhesions or drying-out of
the valves
rinse the metering head through the
suction tube, if necessary remove and
clean or replace the valves
Metering head is leaking,
medium is escaping from
leaking connection
Metering head is loose
Tighten metering head screw diagonally
Diaphragm ruptured
Replace diaphragm
Metering pump does not
work, even though ON-
switch or yellow metering
display (with E20) flashes
pressure-/suction valve is leaking
Clean and rinse valve
Metering volume setting too low
Increase stroke volume setting
Metering pump does not
work, even though ON
pressure-/suction valve is leaking
Clean and rinse valve
Metering volume setting too low
Increase stroke volume setting
Metering valve clogged
Clean and flush the valve
Dosing back pressure too high
Check the metering pipe and return pipe
Once the cause of the fault has been rectified, switch the mains off again and set
the switch to "0" in order to cancel the fault alarm.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Elados EMP II-E10 and is the answer not in the manual?

Ecolab Elados EMP II-E10 Specifications

General IconGeneral
BrandEcolab
ModelElados EMP II-E10
CategoryWater Pump
LanguageEnglish

Related product manuals