95 Installation and Service Guide
Installing System Software
Compatibility: After you upgrade system software, remind the site administrator to upgrade user software on all
computers connected to the E-35A. Using old user software with new system software may negatively affect the
system.
Calibration: All calibrated data are deleted when you install system software. If you need to keep the calibrated
data, export the output profile with the calibration measurement data which you calibrated, export the calibration
measurement data, and then upgrade the system software. After the upgrade, import the output profile and then
the calibration measurement data (.cm0 file).
To export the output profile
1 Launch Command WorkStation and log into the E-35A as administrator.
2 From the Server menu, select Device Center > Resources > Profiles.
3 From the Output Profiles list, select the output profile that you calibrated, and click Export.
4 Specify the location where you want to save the profile and click Select Folder.
To export the calibration measurement data
1 Launch Command WorkStation and log into the E-35A as administrator.
2 From the Server menu, select Device Center > General > Tools.
3 Click Manage in Calibration area.
4 In the Calibrator window, select the calibration settings you want to save, click View Measurement, and then click
Export Measurement.
5 Specify the location where you want to save the measurement data and click Save.
After you upgrade the system software, follow the procedures below to import the output profile and calibration
measurement data.
To import the output profile
1 Launch Command WorkStation and log into the E-35A as administrator.
2 From the Server menu, select Device Center > Resources > Profiles.
3 Click Import and select the profile that you want to import.
4 Navigate to the folder where the output profile is located.
5 Click Open.
To import the calibration measurement data
1 Launch Command WorkStation and log into the E-35A as administrator.
2 From the Server menu, select Device Center > General > Tools > Calibrate.
3 Select the calibration setting (
Plain Paper or Glossy Paper).