EasyManua.ls Logo

Eldes ESIM364 - 4 Setting up Date and Time

Eldes ESIM364
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
13
EN
ESIM364 USER MANUAL V1.6
To assign the master code or a certain user code to a certain partition (-s):
EKB2
Enter the master code, navigate through the following path using OK and arrow keys, select the master code or a certain user
code and enter the partition value you wish the code to assign to.
Master code: OK mmmm OK CODES OK MASTER CODE OK PARTITION OK pv OK
User code 2... 17: ... CODES OK USER CODE (2-17) OK USER CODE 2... 17 OK PARTITION OK pv OK
User code 18... 30: ... CODES OK USER CODE (18-30) OK USER CODE 18... 30 OK PARTITION OK pv OK
Value: mmmm – 4-digit master code; pv – partition value (see table on page 12).
EKB3/
EKB3W
Press ,
5
, enter 01 or user code slot, partition value you wish the code to assign to and the master code:
Master code:
5
01 pv mmmm
User code:
5
us pv mmmm
Value: us - user code slot, range - [02... 30]; pv – partition value (see table on page 12); mmmm - 4-digit master code.
Example:
4
0
2
2 2
2
5
4. SETTING UP DATE AND TIME
NOTE: When the alarm system is connected to a monitoring station the date and time are set automatically. The system retrieves this
data from the monitoring station by itself.
SMS
1. Send the following SMS text message to the phone number of ESIM364 alarm system:
SMS text message content:
ssss_yyyy.mm.dd_hr:mn
Value: ssss - 4-digit SMS password; yyyy – year; mm – month, range – [01... 12]; dd – day, range - [01... 31]; hr – hours, range
– [00... 23], mn – minutes, range – [00... 59].
Example: 1111_2011.12.15_13:45
2. The system will reply with conrmation by SMS text message to user phone number who sent the SMS text message after
the date and time is set successfully.
EKB2
Navigate through the following menu path using OK and arrow keys and enter the date and time values using the number keys:
Menu path:
OK DATE/TIME SET OK yyyy-mm-dd_hr:mn OK
Value: yyyy – year; mm – month, range – [01... 12]; dd – day, range - [01... 31]; hr – hours, range – [00... 23], mn – minutes, range
– [00... 59].
Example: 2015-12-15 13:45