The green indicator indicates that no zones and/or tampers are violated and the system is prepared for arming. Yellow indicator lights
up or ashes in case of zone violation or if system faults are present. The partition cannot be armed until the violated zone (-s) is restored,
disabled, bypassed or set up to operate under Force mode or violated tamper (-s) is restored. By default, the following faults allow partition
arming if present:
• mains power is lost.
• low battery.
• battery dead or missing.
• battery failed.
• siren failed.
• date/time not set.
• GSM connection failed.
• GSM/GPRS antenna failed.
Audio Indication
The built-in buzzer uses two types of sound signals – three short beeps and one long beep. Three short beeps stand for successfully carried
out conguration command, one long beep – for invalid conguration command. In addition, the buzzer emits short beeps in case of alarm.
Visual Indication
EKB3 keys have a LED back-light, therefore it is possible to use this keypad even in dark premises. The back-light lasts for 60 seconds after the last
key-stroke while the system is disarmed. In case of alarm, the keypad back-light turns ON and lasts until the system is disarmed.
EKB3W keys have a LED back-light, which will be activated once any key is pressed. Due to battery power saving reasons, the back-light and
LED light last for 10 seconds after the last key-stroke.
1.4. Partitions
Your alarm system may be partitioned into up to 4 partitions, known as Partition 1 through Partition 4 . Each system partition operates inde-
pendently from each other, therefor partitioning the system allows to use 1 alarm system unit to secure up to 4 dierent areas, for example:
oce and warehouse, house and garage etc. By default, the system is NOT partitioned and all user phone numbers, user codes (except for
master code, which is assigned to all 4 system partitions by default), keypads, iButton keys, zones are assigned to Partition 1.