16
16
EN
ESIM364 USER MANUAL V1.6
5.3. EKB2 Keypad and User/Master Code
icon displayed next to the partition name in the home screen view of EKB2 keypad indicates that no violated zones and/or tampers
are present, therefore the partition is ready for arming. If icon is displayed instead, the partition is unready for arming, therefore the
user must restore all violated zones and/or tampers before arming the partition. Alternatively, the violated zones can be bypassed (see 8.
BYPASSING AND ACTIVATING ZONES), disabled (please, contact your alarm system installer to set up this feature) or a Force attribute
enabled (please, contact your alarm system installer to set up this parameter), while the tampers can be disabled (please, contact your
alarm system installer to set up this feature). icon appears in the home screen view if system fault (-s) exist (see 13. INDICATION OF
SYSTEM FAULTS).
When a user/master code is assigned to multiple partitions, the user will be able arm/disarm the corresponding system partitions by EKB2
keypad using partition selection menu. However, if a user/master code is assigned to Partition 1, 2 and 4, while EKB2 keypad is assigned
to Partition 2, the user will be able to arm/disarm Partition 1, 2 and 4, but the keypad will only display Partition 2 name and the related
information in home screen view. For more details on how to set the keypad partition and user/master code partition, please refer to 3.3.
Assigning User and Master Code Partition and contact your alarm system installer.
5.3.1. Arming the System
To arm the system by EKB2 keypad, enter any out of 29 available 4-digit user codes or master code using the number keys on the keypad
(see 3. MASTER AND USER CODES for user/master code management). By default, the arming process is as follows:
Non-partitioned system - When a valid user code is entered, the system will initiate exit delay, the keypad’s buzzer will emit short
beeps, the keypad will switch to home screen view and display the countdown timer.
Arm the system
Enter user/master code:
uumm OK
Value: uumm – 4-digit user/master code.
Partitioned system - arming a single partition – When a valid user or master code is entered, the keypad will display the partition
selection menu. Once a partition that is to be armed is selected, the system will initiate exit delay. During the exit delay, the keypad’s
buzzer will emit short beeps and the keypad will display ARMING part-name message for 3 seconds followed by partition selection
menu. When the keypad back-light timeout expires, the home screen view will follow. If key is touched twice during exit delay, the
keypad will return to home screen view and display the countdown timer next to the partition name that is being armed.
Arm the system
Enter user/master code and select partition:
uumm OK [p] part-name OK or OK uumm OK ARM/DIS PARTITION OK [p] part-
name OK
Value: uumm – 4-digit user or master code; p – partition number, range – [1... 4], part-name – up to
15 characters partition name
Partitioned system - arming multiple partitions simultaneously – When a valid user or master code is entered, the keypad will
display the partition selection menu. Once ARM ALL menu item is selected the system will proceed as follows:
if all partitions are disarmed-ready (no violated zone/tamper), the system will initiate exit delay. During the exit delay, the keypad’s
buzzer will emit short beeps and the keypad will display multiple ARMING part-name messages for 3 seconds reecting each
partition the user/master code is assigned to, followed by partition selection menu.
if one or more partitions are disarmed-unready (contains violated zone/tamper), the system will initiate exit delay. During the exit
delay, the keypad’s buzzer will emit short beeps and the keypad will display ARMING part-name message (-s) reecting ready
partition (-s), while the unready partition (-s) will be skipped indicated by part-name NOT READY message (-s) followed by
partition selection menu. Each message will be displayed for 2 seconds and corresponds to the partition (-s) the user/master code
is assigned to.
if a combination of armed and disarmed-ready partitions exists, the system will initiate exit delay. During the exit delay, the keypad’s
buzzer will emit short beeps and the keypad will display ARMING part-name message (-s) seconds reecting ready partition (-s),
while the pre-armed partition (-s) will be skipped. Each message will be displayed for 2 seconds and corresponds to the partition (-s)
the user/master code is assigned to.
When the keypad back-light timeout expires, the home screen view will follow. If key is touched twice during exit delay, the keypad will
return to home screen view and display the countdown timers next to the partition names the keypad is assigned to.
Arm all partitions
simultaneously
Enter user/master code:
uumm OK ARM ALL OK or OK uumm OK ARM/DIS PARTITION OK ARM ALL OK
Value: uumm – 4-digit user/master code
When successfully armed:
the countdown timers will disappear.
user will be notied by SMS text message
in addition, the keypad may display icon next to the partition name that has been armed (by default – disabled).