EasyManua.ls Logo

Eldes ESIM364 - 12 Managing and Viewing Temperature Information

Eldes ESIM364
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
28
EN
ESIM364 USER MANUAL V1.6
12. MANAGING AND VIEWING TEMPERATURE INFORMATION
SMS
1. The system supports up to 8 temperature sensors. If at least 1 or 2 (primary and/or secondary) temperature sensors are
installed in your system, it can send an SMS text message containing temperature value in case the set lowest or highest
temperature limit value is exceeded. This SMS text message is sent to User 1 only. By default, conguration by this SMS text
message is disabled.
User
ESIM364
SMS
18
2. In order enable or set a dierent lowest, highest temperature limit value or specify a name for a determined primary or
secondary temperature sensor, send the following SMS text message to the system‘s phone number from any out of 10
listed user phone numbers:
SMS text message content:
ssss_TEMPn:MIN:tm,MAX:tmx,NAME:temp-sens-name
Value: ssss - 4-digit SMS password; n - primary or secondary temperature sensor number, range - [1... 8]; tm - lowest tem-
perature limit boun dary in °C, range - [-55... 125]; tmx - highest temperature limit boundary in °C, range - [-55... 125]; temp-
sens-name - temperature sensor name, length - 4... 24 characters.
Example: 1111_TEMP2:MIN:-15,MAX:30,NAME:Garage
3. In order to disable this SMS text message, send the following SMS text message to the system‘s phone number from any
out of 10 listed user phone numbers:
SMS text message content:
ssss_TEMPn:MIN:0,MAX:0
Value: ssss - 4-digit SMS password; n - primary or secondary temperature sensor number, range - [1... 8].
Example: 1111_TEMP1:MIN:0,MAX:0
4. In order to nd out, which temperature sensors are set as primary and secondary, send the following SMS text message to
the system‘s phone number from any out of 10 listed user phone numbers:
SMS text message content:
ssss_TEMPI?
Value: ssss - 4-digit SMS password.
Example: 1111_TEMPI:?
5. In order to nd out the current temperature of all temperature sensors, send the following SMS text message to the system‘s
phone number from any out of 10 listed user phone numbers:
SMS text message content:
ssss_ITEMP:?
Value: ssss - 4-digit SMS password.
Example: 1111_ITEMP:?
6. The system will reply with conrmation by SMS text message to the user phone number that sent the SMS text message.
User
ESIM364
SMS
SMS
19
See also 9. VIEWING SYSTEM INFORMATION.
EKB2
Enter valid user/master code and navigate through the following path using OK and arrow keys to view real-time temperature
sensor values:
Menu path:
OK uumm OK TEMP SENSORS INFO OK 1... 8
Value: uuuu – 4-digit user or master code.

Other manuals for Eldes ESIM364