16. VIEWING EVENT AND ALARM LOGS
16.1. Event Log
The event log allows to chronologically register up to 500 timestamped records regarding the following system events:
• System start.
• System arming/disarming.
• Zone violated/restored.
• Tamper violated/restored.
• Zone bypassing.
• Wireless device management.
• Temperature deviation by MIN and MAX boundaries.
• System faults.
• Conguration via USB.
• User phone number that initiated the remote conguration.
The event log is of LIFO (last in, rst out) type that allows the system to automatically replace the oldest records with the latest ones.
EKB2
Enter master code and navigate through the following menu path using OK and arrow keys to view the event log:
Menu path:
OK → mmmm → OK → VIEW EVENT LOG → OK
Value: mmmm - 4-digit master code.
16.2. Alarm Log
The alarm log provides a list of last 16 alarm events generated after last arming period. The alarm log can be viewed via EKB2 and includes
only the alarms of the partition that the user/master code is assigned to. Each alarm record includes alarm type, partition number and zone
number. When highlighted, the date and time of the alarm occurrence can be viewed at the bottom of EKB2 screen. In case of alarm, icon
will appear in home screen view of EKB2. The alarm log auto-clears when the next system arming follows or after viewing it via the keypad.
EKB2
Enter user or master code and navigate through the following menu path using OK and arrow keys to view/clear the alarm log:
Menu path:
OK → uumm → OK → ALARM LOG → OK
Value: uumm - 4-digit user or master code.
Syntax of alarm log record: [alarm-type P:p Z:nn]
Value: alarm-type - BURGLARY/FIRE/24H/SILENT/TAMPER/WS LOST, p - partition number, range - [1... 4], nn - zone/tamper
number, range - [1... 76].
#1 example of alarm log record: BURGLARY P:1 Z:1
Value: BURGLARY - Instant, Int. Follower or Delay-type zone alarm; P:1 - Partition 1; Z:1 - zone Z1.
#2 example of alarm log record: TAMPER P:2 Z:13
Value: TAMPER - tamper alarm; P:2 - Partition 2; Z:13 - tamper 13.
#3 example of alarm log record: FIRE P:4 Z:9
Value: FIRE - Fire-type zone alarm; P:4 - Partition 4; Z:9 - zone Z9.
#4 example of alarm log record: WS LOST P:2 Z:14
Value: WS LOST - wireless signal loss alarm; P:2 - Partition 2; Z:14 - tamper 14.