Alternatively, the user can arm multiple partitions one by one (see Partitioned system - arming a single partition above).
NOTE: Before arming all 4 partitions simultaneously, the user/master code must be assigned to all 4 partitions and the keypad partition
switch feature enabled (please, contact your alarm system installer to set up this parameter).
NOTE: If the user fails to enter a correct user/master code 10 times in a row, the system will block the keypad for 2 minutes. While the
keypad is blocked, the system prevents from entering any user/master code. The keypad will automatically unblock once the 2-minute
time has expired.
5.4.2. Cancelling System Arming
To cancel the arming process, enter the user/master code again during exit delay countdown.
5.4.3. Disarming the System and Turning OFF the Alarm
To disarm and turn OFF the alarm, enter any out of 29 available 4-digit user codes or master code using the number keys on the keypad. By
default, the system disarming process is as follows:
• Non-partitioned system – When a valid user/ master code is entered, indicator and the number
1
key will light OFF and the user
will be notied by SMS text message.
Disarm the system and
turn OFF the alarm
Enter user/master code:
uumm
Value: uumm – 4-digit user or master code.
Example:
2 2 2 2
• Partitioned system – disarming a single partition – To disarm a dierent partition than the keypad is assigned to, use keypad
partition switch feature (by default – disabled; please, contact your alarm system installer to set up this parameter) before the disarming
process.
Switch keypad parti-
tion
Hold the
4
1
key and release it after 3 short beeps:
Value:
4
1
key – partition number 1... 4 respectively.
Once the partition is switched and a valid user/master code is entered, indicator and the number
4
1
key, indicating the partition
that has been disarmed, will light OFF and the user will be notied by SMS text message.
Disarm the system and
turn OFF the alarm
Enter user/master code:
uumm
Value: uumm – 4-digit user or master code.
Example:
2 2 2 2
• Partitioned system - disarming all 4 partitions simultaneously – If a user/master code assigned to all 4 partitions exists, user can
disarm and turn OFF the alarm in all partitions simultaneously. When this feature is used, the system will proceed as follows:
• if all partitions are armed and a valid user/master code is entered, indicator along with the number
1
,
2
,
3
and
4
keys
will light OFF and the user will be notied by SMS text message.
• if one or more partitions are disarmed unready (keypad number
4
1
key ashing, indicating the partition that contains violated
zone/tamper), the system will deny simultaneous partition disarming until the partition’s zone/tamper violation is removed.
• if a combination of armed and disarmed ready partitions is present, the system will initiate exit delay. During the exit delay, the
keypad’s buzzer will emit short beeps and keypad indicator (if the keypad is switched to a disarmed partition) along with the
number
4
1
key, indicating the partition that is to be armed, will light ON. The disarmed-ready partitions will be armed and
the pre-armed ones will be skipped. In order to disarm all 4 partitions simultaneously, the user must repeat the following command:
Disarm and turn OFF
the alarm in all 4 parti-
tions simultaneously
Hold the
Alternatively, the user can disarm and turn OFF the alarm in multiple partitions one by one (see Partitioned system - disarming a single
partition above).
NOTE: If the user fails to enter a correct user/master code 10 times in a row, the system will block the keypad for 2 minutes. While the
keypad is blocked, the system prevents from entering any user/master code. The keypad will automatically unblock once the 2-minute
time has expired.
NOTE: Before disarming all 4 partitions simultaneously, the user/master code must be assigned to all 4 partitions and the keypad partition
switch feature enabled (please, contact your alarm system installer to set up this parameter).