Technical Support - MDM 88/97 599 76 11-68 Rev. 01
14.4.3 Drain water circuit
14.4.3.1 Drain pump
Remove the worktop (see relevant paragraph).
Remove the control panel (see relevant paragraph).
Remove the iron ring securing the bellow seal to the front panel.
Unfasten the screws securing the door safety interlock (see related paragraph).
Remove the front panel (see relevant paragraph).
Pull out the main drain pipe.
Remove the protection from the pump.
Move tooth 1 (take care not to break it).
Turn pump 2 in a clockwise direction and simultaneously extract it
from the filter body 3.
Remove the connectors from the pump.