Components activated Working conditions Function tested LCD display
11
TC 3-2
- Reading/Deleting the last alarm ----- ----
TC 4
12
÷
14
TC 3-2
- The LEDs, groups of symbols
in the LCD screen and the
backlight of the display are
turned on in sequence
- Touch a sensor to turn on the
group of icons in the LCD
screen or the corresponding
LED and the buzzer sounds at
the same time
Always active
User interface
functioning
TC 4
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining the
water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is higher
than 80°C, heating does not take place).
(**) The check at the maximum speed occurs without control of the A.G.S. and no garments must be inside the appliance.
Technical Support - DMM 37/124 599 75 58-67 Rev.04