1
Read Carefully !
ENGLISH Version
R36-01-18
OPERATING INSTRUCTIONS F O R
MAX5” INSTRUMENT
This manual contains safety information that if ignored
can endanger life or result in serious injury. They are
indicated by this icon.
Keep the instrument protected from sun and water.
Avoid water splashes.
Configuration and screenshots may be different and not including
some functions. A maximum of 5 channels can be set.
DOWNLOAD ERMES COMMUNICATION SOFTWARE
www.ermes-server.com
Question and Answer IconNeed help?

Do you have a question about the Emec MAX5 and is the answer not in the manual?

Summary

Introduction

The Wheel Control

Description of the instrument's wheel control interface for navigation and selection.

Mainboard Connections

Power Connections

Information on main fuse, circuit fuse, and main power supply connections.

I;O Connections

Details on various input/output connections like setpoint, probe cleaning, and general alarm.

I;O Connection Details

Comprehensive list and description of various input/output terminal assignments and functions.

Main Screen Overview

Connection Status Indicators

Explanation of different network connection status indicators shown on the display.

Status Control Navigation

Details on how to scroll through different status views like inputs, outputs, and alarms.

Log Entries Viewing

Information about viewing logged events and system status entries.

Service Information Display

Display of device ID, software version, and code number for service purposes.

Setup Menu Access

Accessing the passcode-protected setup menu for instrument configuration.

Turn Off Instrument Procedure

Procedure to turn off the instrument safely from the main menu.

Alarm Menu Access

Accessing the menu to stop active alarms and manage alarm conditions.

Passcode Protection

Enter Passcode

Explanation of the passcode entry mechanism for protected areas.

Setup Navigation

Setpoint Option Configuration

Configuring instrument operating modes, outputs, and alarm conditions.

Calibration Option Access

Accessing the calibration menu for instrument readings.

General Options Menu

Accessing various sub-menus like TAU, clock, and RS485 setup.

Manual Operations Activation

Activating outputs manually for testing purposes.

Exit Setup Procedure

Returning to the main screen from the setup menu.

Setpoint Configuration

Da and Db Output Controls

Controlling setpoint and level outputs using Da and Db functions.

Da and Db Working Modes

ON;OFF Mode Setup

Setting up ON/OFF mode with parameters like ON, OFF, IN, RL, STOP, and MSG.

PWM Mode Configuration

PWM Mode Parameters

Details on parameters like Unit Value + %, IN, RL, STOP, and MSG for PWM mode.

PID Mode Operation

PID Mode Parameters

Details on parameters like IN, RL, STOP, ON, OFF, I, and D for PID mode.

Proportional Pump Outputs (Pa & Pb)

Proportional Output Selection (OUT)

Selecting proportional pump outputs from available options.

Proportional Input Assignment (IN)

Assigning input numbers for proportional pump outputs.

Proportional Stop Condition (STOP)

Setting stop conditions for proportional pump outputs.

Proportional Message Alerts (MSG)

Configuring SMS/EMAIL alerts for proportional pump outputs.

pH-Pulse Modulation (pH-PM)

Setting pH values for proportional pulse output control.

mA Output Configuration

mA Output Selection (Out)

Selecting mA outputs from available terminal assignments.

mA Input Assignment (IN)

Assigning input numbers for mA outputs.

mA Stop Condition (STOP)

Setting stop conditions for mA outputs.

mA Message Alerts (MSG)

Configuring SMS/EMAIL alerts for mA outputs.

pH to mA Mapping (pH-mA)

Setting pH values for proportional mA output control.

Alarm Configuration (Aa & Ab)

Alarm Settings

Configuring alarm conditions (ON/OFF) and trigger values.

Alarm Delay Setting

Setting a delay period before an alarm is triggered.

Alarm Messaging Setup

Configuring SMS/EMAIL notifications for alarms.

Maximum Dosing Time (AD)

AD Alarm Messaging

Configuring SMS/EMAIL notifications for the AD alarm.

Stable Reading Alarm (AR)

AR Alarm Messaging

Configuring SMS/EMAIL notifications for the AR alarm.

Instrument Calibration

pH Calibration Procedure

Step-by-step guide for calibrating the pH probe using buffer solutions.

pH 1 st Point Calibration

Procedure for performing the first point calibration for pH.

pH 2 nd Point Calibration

Procedure for performing the second point calibration for pH.

pH Temperature Compensation

Enabling automatic or manual temperature compensation for pH calibration.

Chlorine (CI) Calibration

Select Chlorine Probe

Choosing the appropriate Chlorine probe from the available list.

Chlorine Zero Calibration

Performing the zero calibration for the Chlorine probe.

Chlorine 2 nd Point Calibration

Performing the second point calibration for the Chlorine probe.

ORP (mV) Calibration

Turbidity (NTU) Range Setup

Temperature Probe Calibration

Conductivity (uS) Calibration

Conductivity Working Scale

Selecting the appropriate measurement scale for conductivity.

Conductivity 1 st Point Calibration

Performing the first point (zero) calibration for conductivity.

Conductivity 2 nd Point Calibration

Performing the second point calibration for conductivity.

Conductivity Temperature Compensation

Configuring automatic or manual temperature compensation for conductivity.

Timer Configuration

Timer Output Selection

Selecting outputs to be enabled during the timer's active period.

Timer Start Time (Ton)

Setting the starting time for the timer activity.

Timer End Time (Toff)

Setting the ending time for the timer activity.

Timer Day Selection

Selecting days of the week for timer activation.

Timer 2 to 5 Configuration

Timer 2-5 Output Selection

Selecting outputs for timer 2 to 5 activation.

Timer 2-5 Start Time (Ton)

Setting the start date and time for timer 2 to 5.

Timer 2-5 End Time (Toff)

Setting the end time for timer 2 to 5.

Timer Repeat Interval (Loop)

Defining the repeat interval (days) for timer activities.

System Options Menu

TAU Setting

Adjusting display response speed to probe readings.

Delay Outputs and SMS

Setting pump output activation delay and SMS/email alerts.

Flow Monitoring (FM Counter)

Enabling and configuring flow monitoring using a pulse sender water meter.

Flow Detect Configuration

Configuring flow sensor input (Direct, Reverse, Disable) and related alerts.

Clock Setup

Setting the instrument's date and time according to local or international format.

Probe Cleaning Setup

Enabling and configuring the automatic probe cleaning function.

EEPROM Reset Procedure

Restoring the instrument to its original factory settings.

RS485 Communication Setup

Configuring the instrument's ID number and name for RS485 communication.

GSM Modem Configuration

GSM Signal Status Check

Checking the GSM modem's signal strength for reliable SMS transmission.

GSM Modem Version Info

Interpreting antenna icons and blinking/fixed envelope indicators for modem status.

TCP;IP Network Configuration

IP Address Explained

Explanation of static vs. dynamic IP addresses and their usage.

GPRS Modem Configuration

GPRS SIM PIN Entry

Entering the SIM card PIN if required for GPRS communication.

GPRS ERMES Server Enable

Enabling or disabling ERMES communication via the SIM card.

GPRS APN Setup

Manually entering the APN for internet access.

Email Alert Configuration

Alarm Setup Configuration

Log Setup Configuration

Passcode Change

Manual Output Control

Manual Relay Activation

Manually activating setpoint relay outputs.

Manual Pulse Activation

Manually activating proportional pump outputs with selectable pulses.

Manual mA Activation

Manually activating mA outputs with selectable current values.

Manual Level Status

Viewing tank level input status.

Appendix A: Probe Connections

Chlorine Module Connections

Specific connection details for Chlorine probes.

Appendix: Conductivity Modules

Appendix: Turbidity Probe Connections

Appendix: Dissolved Oxygen Probe Connections

Appendix: Potentiostat Probe Connections

Self Clean Menu Configuration

Configuring the automatic probe cleaning cycle, time, and restore settings.

pH & Temperature Compensation

Enabling pH and temperature compensation within the calibration menu.

Appendix: Inductive Conductivity Probe Connections

Appendix B: Installation Diagram

Appendix C: Network Logical Scheme

Appendix D: USB Data Logging Module

Record Activities to USB

Steps to save instrument activities to a USB pendrive.

Review USB Log Data

How to access recorded data via the ERMES web interface.

Appendix E: EOLUM Probe Setup and Calibration

EOLUM Calibration in Air

Performing dissolved oxygen probe calibration in ambient air.

EOLUM Calibration in Water

Performing dissolved oxygen probe calibration in saturated water.

EOLUM Calibration with Reference

Performing dissolved oxygen probe calibration using a reference solution.

EOLUM Temperature Sensor Calibration

Calibrating the temperature sensor associated with the EOLUM probe.

Appendix F: MODBUS Setup

MODBUS Baud Rate Setting

Setting the communication speed for MODBUS.

MODBUS ID Assignment

Assigning a unique address for MODBUS communication.

Appendix G: SETPOINT Temperature Control

Appendix H: Water Salinity Chart

Appendix I: Fluorine Probe Calibration

Fluorine Probe Zero Point (P1)

Performing the first point (zero) calibration for the Fluorine probe.

Fluorine Probe Second Point (P2)

Performing the second point calibration for the Fluorine probe.

Appendix L: Chlorine Index and Serial Number

Appendix: WIFI Connection Setup

Select Available WiFi Network

Selecting a WiFi network from the available list.

Scan for WiFi Networks

Scanning for available WiFi networks.

Save WiFi Configuration

Saving WiFi network configuration settings.

Emec MAX5 Specifications

General IconGeneral
CategoryControl Systems
Power Supply24 VDC
Operating Temperature-20°C to +70°C
Input Voltage0-10VDC, 4-20mA (Analog)
Output Voltage0-10VDC (Analog)
Current Output4-20mA (Analog)
Communication InterfaceRS485, CAN
Protection ClassIP65