Description of the instrument's wheel control interface for navigation and selection.
Information on main fuse, circuit fuse, and main power supply connections.
Details on various input/output connections like setpoint, probe cleaning, and general alarm.
Comprehensive list and description of various input/output terminal assignments and functions.
Explanation of different network connection status indicators shown on the display.
Details on how to scroll through different status views like inputs, outputs, and alarms.
Information about viewing logged events and system status entries.
Display of device ID, software version, and code number for service purposes.
Accessing the passcode-protected setup menu for instrument configuration.
Procedure to turn off the instrument safely from the main menu.
Accessing the menu to stop active alarms and manage alarm conditions.
Explanation of the passcode entry mechanism for protected areas.
Configuring instrument operating modes, outputs, and alarm conditions.
Accessing the calibration menu for instrument readings.
Accessing various sub-menus like TAU, clock, and RS485 setup.
Activating outputs manually for testing purposes.
Returning to the main screen from the setup menu.
Controlling setpoint and level outputs using Da and Db functions.
Setting up ON/OFF mode with parameters like ON, OFF, IN, RL, STOP, and MSG.
Details on parameters like Unit Value + %, IN, RL, STOP, and MSG for PWM mode.
Details on parameters like IN, RL, STOP, ON, OFF, I, and D for PID mode.
Selecting proportional pump outputs from available options.
Assigning input numbers for proportional pump outputs.
Setting stop conditions for proportional pump outputs.
Configuring SMS/EMAIL alerts for proportional pump outputs.
Setting pH values for proportional pulse output control.
Selecting mA outputs from available terminal assignments.
Assigning input numbers for mA outputs.
Setting stop conditions for mA outputs.
Configuring SMS/EMAIL alerts for mA outputs.
Setting pH values for proportional mA output control.
Configuring alarm conditions (ON/OFF) and trigger values.
Setting a delay period before an alarm is triggered.
Configuring SMS/EMAIL notifications for alarms.
Configuring SMS/EMAIL notifications for the AD alarm.
Configuring SMS/EMAIL notifications for the AR alarm.
Step-by-step guide for calibrating the pH probe using buffer solutions.
Procedure for performing the first point calibration for pH.
Procedure for performing the second point calibration for pH.
Enabling automatic or manual temperature compensation for pH calibration.
Choosing the appropriate Chlorine probe from the available list.
Performing the zero calibration for the Chlorine probe.
Performing the second point calibration for the Chlorine probe.
Selecting the appropriate measurement scale for conductivity.
Performing the first point (zero) calibration for conductivity.
Performing the second point calibration for conductivity.
Configuring automatic or manual temperature compensation for conductivity.
Selecting outputs to be enabled during the timer's active period.
Setting the starting time for the timer activity.
Setting the ending time for the timer activity.
Selecting days of the week for timer activation.
Selecting outputs for timer 2 to 5 activation.
Setting the start date and time for timer 2 to 5.
Setting the end time for timer 2 to 5.
Defining the repeat interval (days) for timer activities.
Adjusting display response speed to probe readings.
Setting pump output activation delay and SMS/email alerts.
Enabling and configuring flow monitoring using a pulse sender water meter.
Configuring flow sensor input (Direct, Reverse, Disable) and related alerts.
Setting the instrument's date and time according to local or international format.
Enabling and configuring the automatic probe cleaning function.
Restoring the instrument to its original factory settings.
Configuring the instrument's ID number and name for RS485 communication.
Checking the GSM modem's signal strength for reliable SMS transmission.
Interpreting antenna icons and blinking/fixed envelope indicators for modem status.
Explanation of static vs. dynamic IP addresses and their usage.
Entering the SIM card PIN if required for GPRS communication.
Enabling or disabling ERMES communication via the SIM card.
Manually entering the APN for internet access.
Manually activating setpoint relay outputs.
Manually activating proportional pump outputs with selectable pulses.
Manually activating mA outputs with selectable current values.
Viewing tank level input status.
Specific connection details for Chlorine probes.
Configuring the automatic probe cleaning cycle, time, and restore settings.
Enabling pH and temperature compensation within the calibration menu.
Steps to save instrument activities to a USB pendrive.
How to access recorded data via the ERMES web interface.
Performing dissolved oxygen probe calibration in ambient air.
Performing dissolved oxygen probe calibration in saturated water.
Performing dissolved oxygen probe calibration using a reference solution.
Calibrating the temperature sensor associated with the EOLUM probe.
Setting the communication speed for MODBUS.
Assigning a unique address for MODBUS communication.
Performing the first point (zero) calibration for the Fluorine probe.
Performing the second point calibration for the Fluorine probe.
Selecting a WiFi network from the available list.
Scanning for available WiFi networks.
Saving WiFi network configuration settings.
| Category | Control Systems |
|---|---|
| Power Supply | 24 VDC |
| Operating Temperature | -20°C to +70°C |
| Input Voltage | 0-10VDC, 4-20mA (Analog) |
| Output Voltage | 0-10VDC (Analog) |
| Current Output | 4-20mA (Analog) |
| Communication Interface | RS485, CAN |
| Protection Class | IP65 |