Daniel 3410 Series Gas Ultrasonic Meter Operations Manual Miscellaneous equations
3-9000-777 Rev E January 2018
Miscellaneous conversion factors 141
A
Appendix B: Miscellaneous equations
B.1 Miscellaneous conversion factors
K-Factor and Inverse K-Factor
Equation B-1 Frequency Volumetric Flow Rate K-Factor
and
Equation B-2 Frequency Volumetric Flow Rate Inverse K-Factor
where
=
frequency “K-Factor” (pulses/m
3
or pulses/ft
3
) (Freq1KFactor and
Freq2KFactor)
=
frequency “Inverse K-Factor” (m
3
/pulse or ft
3
/pulse)
(Freq1InvKFactor and Freq2InvKFactor)
=
frequency full-scale volumetric flow rate (m
3
/h or ft
3
/h)
(Freq1FullScaleVolFlowRate and Freq2FullScaleVolFlowRate)
=
maximum frequency (Hz = pulses/s) (Either 1000 or 5000 Hz)
(Freq1MaxFrequency and Freq2MaxFrequency)
KFactor
MaxFreq()3600shr()
FreqQ
FullSc ale
----------------------------------------------------------
=
InvKFactor
FreqQ
FullScale
MaxFreq()3600shr()
----------------------------------------------------------
=
KFactor
InvKFactor
FreqQ
FullScale
MaxFreq

Table of Contents

Other manuals for Emerson Daniel 3410 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel 3410 Series and is the answer not in the manual?

Emerson Daniel 3410 Series Specifications

General IconGeneral
BrandEmerson
ModelDaniel 3410 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals