3410 Series Gas Ultrasonic Meters Operations Manual Section 5: Calibrate and configure the meter
3-9000-777 Rev E January 2018
Configure Frequency/Digital output sources 57
5.4.2 Configure Frequency/Digital output sources
The meter has three user-configurable selections for configuring either a Frequency output or
Digital output (FODO).
FODO1 (eight possible parameter configurations)
FODO2 (eight possible parameter configurations)
FODO3 (eight possible parameter configurations)
FODO4 (eight possible parameter configurations)
FODO5 (eight possible parameter configurations)
FODO6 (eight possible parameter configurations)
Frequency or Digital Outputs (FODO 1, FODO6) source options
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is based on frequency content (Actual - Uncorrected Flow Rate or
Corrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1 B Phase
Frequency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency1A Validity and Flow
Direction)
Digital output 2A is based on Digital output 2A content (Frequency Output 2 Validity and
Flow Direction)
Digital output 2B is based on Digital output 2B content (Frequency Output 2 Validity and
Flow Direction)
Frequency or Digital Outputs (FODO2, FODO3, FODO4, FODO5) source
options
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is based on frequency 1 content (Actual - Uncorrected Flow Rate or
Corrected Flow Rate)
Frequency output 1B is based on frequency 1 content and Frequency 1B Phase
Frequency output 2A is based on frequency 2 content (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency 2 content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency 1A Validity and Flow
Direction)
Digital output 1B is based on Digital output 1B content (Frequency 1A Validity and Flow
Direction)
Digital output 2A is based on Digital output 2A content (Frequency 2A Validity and Flow
Direction)
Digital output 2B is based on Digital output 2B content (Frequency 2B Validity and Flow
Direction)
Mode options
Open Collector (requires external excitation supply voltage and pull-up resistor)

Table of Contents

Other manuals for Emerson Daniel 3410 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel 3410 Series and is the answer not in the manual?

Emerson Daniel 3410 Series Specifications

General IconGeneral
BrandEmerson
ModelDaniel 3410 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals