3410 Series Gas Ultrasonic Meters Operations Manual Section 5: Calibrate and configure the meter
3-9000-777 Rev E January 2018
Configure Frequency/Digital output sources 57
5.4.2 Configure Frequency/Digital output sources
The meter has three user-configurable selections for configuring either a Frequency output or
Digital output (FODO).
• FODO1 (eight possible parameter configurations)
• FODO2 (eight possible parameter configurations)
• FODO3 (eight possible parameter configurations)
• FODO4 (eight possible parameter configurations)
• FODO5 (eight possible parameter configurations)
• FODO6 (eight possible parameter configurations)
Frequency or Digital Outputs (FODO 1, FODO6) source options
• FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
• Frequency output 1A is based on frequency content (Actual - Uncorrected Flow Rate or
Corrected Flow Rate)
• Frequency output 1B is based on frequency content and Frequency 1 B Phase
• Frequency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
• Frequency output 2B is based on frequency content and Frequency 2B Phase
• Digital output 1A is based on Digital output1A content (Frequency1A Validity and Flow
Direction)
• Digital output 2A is based on Digital output 2A content (Frequency Output 2 Validity and
Flow Direction)
• Digital output 2B is based on Digital output 2B content (Frequency Output 2 Validity and
Flow Direction)
Frequency or Digital Outputs (FODO2, FODO3, FODO4, FODO5) source
options
• FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
• Frequency output 1A is based on frequency 1 content (Actual - Uncorrected Flow Rate or
Corrected Flow Rate)
• Frequency output 1B is based on frequency 1 content and Frequency 1B Phase
• Frequency output 2A is based on frequency 2 content (Actual - Uncorrected Flow Rate)
• Frequency output 2B is based on frequency 2 content and Frequency 2B Phase
• Digital output 1A is based on Digital output1A content (Frequency 1A Validity and Flow
Direction)
• Digital output 1B is based on Digital output 1B content (Frequency 1A Validity and Flow
Direction)
• Digital output 2A is based on Digital output 2A content (Frequency 2A Validity and Flow
Direction)
• Digital output 2B is based on Digital output 2B content (Frequency 2B Validity and Flow
Direction)
Mode options
• Open Collector (requires external excitation supply voltage and pull-up resistor)