EasyManuals Logo

Emerson Daniel 3410 Series User Manual

Emerson Daniel 3410 Series
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
Daniel 3410 Series Gas Ultrasonic Meter Operations Manual Miscellaneous equations
3-9000-777 Rev E January 2018
Chord “L” dimension calculation 143
B.2 Chord “L” dimension calculation
The chord “L” dimension is calculated from the meter housing length as well as the
transducer pair lengths, mount lengths, holder lengths, and stalk lengths as shown in
Equation B-5. The transducer lengths are etched on the transducers. Likewise, the lengths
of the mounts, stalk assemblies, and transducer holders are also etched on the individual
components. The length of the meter body is found on the original calibration sheet
supplied with the meter.
Equation B-5 Chord “L” Dimension
where
=
chord “L” dimension (in) (LA ... LD)
=
meter housing length (in)
=
transducer 1 mount length (in)
=
transducer 2 mount length (in)
=
transducer 1 length (in)
=
transducer 2 length (in)
=
transducer 1 stalk length (in)
=
transducer 2 stalk length (in)
=
transducer 1 holder length (in)
=
transducer 2 holder length (in)
L
chord
L
MeterHou gsin
L
Mount1
L
Mount2
++=
L
Xdcr1
L
Stalk1
L
Hldr1
L
Xdcr2
L
Stalk2
L
Hldr2
L
chord
L
MeterHou gsin
L
Mount1
L
Mount2
L
Xdcr1
L
Xdcr2
L
Stalk1
L
Stalk2
L
Hldr1
L
Hldr2

Table of Contents

Other manuals for Emerson Daniel 3410 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel 3410 Series and is the answer not in the manual?

Emerson Daniel 3410 Series Specifications

General IconGeneral
BrandEmerson
ModelDaniel 3410 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals