• Outputs Test
• Transduce Swap-Out
• Program Download
• Communications Analyzer
Log/Reports
• Maintenance logs and reports
• Trend maintenance logs
• Meter archive logs
• Compare Excel
®
meter configurations
Calibration
• Analog inputs
• Meter Factors
• Flow calibration
Setup the meter directory
Setup the connection properties for your meter. By default, the meter directory contains
only one record named New Meter, that is defaulted to connect to a Daniel Gas Ultrasonic
meter configured as shipped from the factory.
Create a new meter record
1. Select Insert, Insert Duplicate, or Add from the File pull-down menu to create a new
record.
2. Setup the record by entering a Meter Name, Short Desc, Meter Type, and select the
connection type(s) checkboxes Direct, Modem, Ethernet.
3. For each connection type selected, a button will be enabled at the bottom of the
dialog with the same name. Click these buttons to edit the connection properties for
that connection method. After choosing the connection properties, click OK accept
the changes or Click Cancel to discard any changes and close the dialog.
a. Direct connection - to connect to the meter directly through one of the serial
ports on the meter using one of the serial ports on your computer. Click Direct to
set the following parameters.
• Protocol: TCP/IP is a read-only field and is the only protocol Daniel MeterLink
uses.
Note:Daniel Ultrasonic meters still support Modbus ASCII and Modbus RTU
when talking to other applications or devices.
• Comms Address: Enter the communication address that is configured in the
meter hardware. The default address for meters from the factory is 32. For
Daniel Ultrasonic meters the valid range is from 1 to 247.
Communications
4 3410 Series Gas Ultrasonic Flow meters