GFK-3111A                                 PACMotion VFD AC Variable Speed Drive User Guide  43
Resetting the Drive Following a Trip
PACMotion VFD has many protection features, designed to protect both the drive and motor from accidental 
damage. When any of these protection features are activated, the drive will trip, and display a fault message. 
The fault messages are listed in section Fault Messages on page 90.
When a trip occurs, after the cause of the trip has been investigated and rectied, the user can reset the trip 
in one of the following ways:
•  Press the keypad Stop key.
•  Power off the drive completely, then power on again.
•  If P1-13 > 0, switch off digital input 1, then back on again.
•  If P1-12 = 4, reset via the eldbus interface.
•  If P1-12 = 6, reset via CAN.
Keypad Shortcuts
The following shortcuts can be used to speed up selecting and changing parameters when using the keypad.
Selecting the Parameter Groups
When extended or advanced parameter access is enabled (see section Extended Parameters on page 56), 
additional parameter groups are visible, and may be selected quickly by the following method.
TFT and OLED Display :
Maximum frequency/Speed limit
Preset frequency/Speed 1
P1-01 P2-01
  50.0 Hz   5.0 Hz
Whilst in the parameter 
selection menu, press 
the Navigate and Up or 
Navigate and Down keys 
simultaneously.
The next highest or lowest 
accessible parameter group 
will be selected.
Selecting the Lowest Parameter in a Group
TFT and OLED Display :
Motor rated current
Maximum frequency/Speed limit
P1-08 P1-01
  9.5 A   50.0 Hz
Whilst in the parameter 
selection menu, press 
the Up and Down keys 
simultaneously.
The next lowest accessible 
parameter in the selected 
parameter group will be 
selected.