EasyManua.ls Logo

Emerson Rosemount 8800D Series - Coaxial Cable at the Electronics Housing

Emerson Rosemount 8800D Series
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
103
Reference Manual
00809-0100-4772, Rev FA
Troubleshooting
March 2016
Troubleshooting
7.5.7 Coaxial cable at the electronics housing
Removing the coaxial cable from the electronics housing
1. Loosen the two housing screws from the housing adapter.
2. Remove the housing adapter from the housing.
3. Loosen and remove the coaxial cable nut from the base of the electronics housing.
4. Remove the coaxial cable ground connection from the housing base by loosening
the housing base screw that is connecting it to the housing base.
5. Loosen the conduit adapter (or cable gland) from the housing adapter.
Removing the coaxial cable
1. Remove the coaxial cable ground wire from the housing adapter
Figure 7-15. Remote Electronics Exploded View
A.Ground connection
B. Housing base screw
C. Housing adapter
D. Housing adapter screws
E. Conduit adapter (optional—supplied by customer)
F. Coaxial cable nut
G. Electronics housing
2. Loosen the conduit adapter (or cable gland) from the
housing adapter.
A
C
D
G
F
B
E