Reference Manual
00809-0100-4772, Rev FA
Resource Block
March 2016
65
Resource Block
Section 5 Resource Block
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 65
Parameters and descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 65
5.1 Overview
This section contains information on the flowmeter resource block. Descriptions of all
resource block parameters, errors, and diagnostics are included. Also the modes, alarm
detection, status handling, Virtual Communication Relationships (VCRs), and troubleshoot-
ing are discussed.
5.1.1 Definition
The resource block defines the physical resources of the device, including type of
measurement, memory, etc. The resource block also handles functionality, such as shed
times, that is common across multiple blocks. The block has no linkable inputs or outputs
and it performs memory-level diagnostics.
5.2 Parameters and descriptions
Table 5-1 lists all of the configurable parameters of the resource block, including the
descriptions and index numbers for each parameter.
Table 5-1. Resource Block Parameters
Parameter
Index
number
Description
ACK_OPTION 38 ACK_OPTION is a selection of whether alarms associated with the function
block will be automatically acknowledged.
ADVISE_ACTIVE 92 Enumerated list of advisory conditions within a device. All open bits are free to
be used as appropriate for each specific device. This parameter is the Read
Only copy of FD_MAINT_ACTIVE & FD_CHECK_ACTIVE.
ADVISE_ALARM 81 Alarm indicating advisory alarms. These conditions do not have a direct
impact on the process or device integrity.
ADVISE_ENABLE 90 Enabled ADVISE_ALM alarm conditions. Corresponds bit for bit to the
ADVISE_ACTIVE. A bit on means that the corresponding alarm condition is
enabled and will be detected. A bit off means the corresponding alarm
condition is disabled and will not be detected.
This parameter is the Read Only copy of FD_MAINT_MAP & FD_CHECK_MAP.