GeneratorUnderVoltageShutdown
GeneratorUnderVoltagePre-Alarm
GeneratorUnderVoltagePre-AlarmReset
GeneratorOverVoltageShutdown
GeneratorOverVoltagePre-Alarm
320
340
350
440
60(dis) 600
60 600
420
400
GeneratorOverVoltagePre-AlarmReset
VV
VV
Undervoltshutdown
Undervoltprealarm
Undervoltreset
Overvoltshutdown
Overvoltprealarm
Overvoltreset
Unit
Shutdowndelaytime
GeneratorVoltageShutdownDelay Time
GENERATOR VOLT LEVEL ( )Generator-> levelVolt
0.0 10.0 1.0
Sec
75.0
30.0(dis)
75.0
75.0
Hz
30.0(dis)
Min
Default
Max
GeneratorUnderFrequencyPre-Alarm
GeneratorUnderFrequencyPre-AlarmReset
GeneratorOverFrequencyShutdown
GeneratorOverFrequencyPre-Alarm
GeneratorOverFrequencyPre-AlarmReset
45.0
46.0
58.0
55.0
54.0
GeneratorFrequencyShutdownDelay Time
Hz
Hz
Hz
Hz
30.0
30.0(dis)
30.0
75.0
75.0
Underfreqprealarm
Underfreqreset
Overfreqshutdown
Overfreqprealarm
Overfreqreset
Shutdowndelaytime
Unit
GENERATOR LEVEL ( )FREQ Generator-> levelFrequency
75.0
75.0
Hz
30.0
Nominal AlternatorFrequency
50.0
43.0
Hz
Nominalfrequency
Underfreqshutdown
GeneratorUnderFrequencyShutdown
30.0(dis)
0.0 10.0 1.0
Sec
Min
Default
Max
GeneratorUnderCurrentPre-AlarmReset
GeneratorOverCurrentSet
GeneratorOverCurrentPre-Alarm
GeneratorOverCurrentPre-AlarmReset
Undercur. reset
Overcur.set
Overcur.prealarm
Overcur. reset
Unit
GENERATOR ( )CUR LEVEL Generator->Current level
GeneratorUnderCurrentSet
Undercur.set
Undercur.prealarm
GeneratorUnderCurrentPre-Alarm
0 9999 9980
AV
0
0(dis)
0
0
0(dis)
9999
9999
9999
9999
9999
1
dis
5
9999
9990
AV
AV
AV
AV
AV
4.1.1 Generator
4.1OperatorParameters
21
Note: dis=disable
4.Parameters
9999
9999
9999
9999
9999
9999
kVA
kVA
kVA
kVA
0(dis)
0(dis)
0
0(dis)
0(dis)
0
Min
Default
Max
GeneratorUnder ShutdownPower
GeneratorUnder Pre-AlarmPower
GeneratorUnder Pre-AlarmResetPower
GeneratorOver ShutdownPower
GeneratorOver Pre-AlarmPower
dis
5
GeneratorOver Pre-AlarmResetPower
kVA
kVA
Under shutdownpower
Under prealarmpower
Under resetpower
Over shutdownpower
Over prealarmpower
Over resetpower
Unit
Shutdowndelaytime
Reversepowerset
Generator ShutdownDelay TimePower
ReversePowerSet
GEN LEVEL ( )POWER Generator->Power level
0
-9999
99
0
2
0
Sec
kW
dis
dis
0
dis