27
75.0
30.0(dis)
75.0
75.0
Hz
30.0(dis)
Min
Default
Max
GeneratorUnderFrequencyPre-Alarm
GeneratorUnderFrequencyPre-AlarmReset
GeneratorOverFrequencyShutdown
GeneratorOverFrequencyPre-Alarm
GeneratorOverFrequencyPre-AlarmReset
45.0
46.0
58.0
55.0
54.0
GeneratorFrequencyShutdownDelay Time
Hz
Hz
Hz
Hz
30.0
30.0(dis)
30.0
75.0
75.0
Underfreqprealarm
Underfreqreset
Overfreqshutdown
Overfreqprealarm
Overfreqreset
Shutdowndelaytime
Unit
GENERATOR LEVEL ( )FREQ Generator-> levelFrequency
75.0
75.0
Hz
30.0
Nominal AlternatorFrequency
50.0
43.0
Hz
Nominalfrequency
Underfreqshutdown
GeneratorUnderFrequencyShutdown
30.0(dis)
0.0 10.0 1.0
Sec
Min
Default
Max
GeneratorUnderCurrentPre-AlarmReset
GeneratorUnderCurrent ActionsDelay Time
GeneratorOverCurrentSet
GeneratorOverCurrentPre-Alarm
GeneratorOverCurrentPre-AlarmReset
GeneratorOverCurrent ActionsDelay Time
GeneratorShortCircuitCurrentSet
Undercur. reset
Undercur.act.
Underact.delaytime
Overcur.set
Overcur.prealarm
Overcur. reset
Overcur.act.
Overact.delaytime
Shortcircuitcur.
Unit
GEN ( )CUR LEVEL & ACT Generator->Current level & act.
GeneratorUnderCurrentSet
Undercur.set
Undercur.prealarm
GeneratorUnderCurrentPre-Alarm
0
0(dis)
0
0
9999
3
99
9999
9980
dis
2
9999
AV
AV
0
0(dis)
0
0(dis)
0
0
0(dis)
9999
9999
9999
3
99
9999
9999
1
dis
5
dis
2
9999
9990
AV
AV
AV
AV
AV
Sec
Sec
GeneratorUnderCurrent Actions
Disable
Warning(AlarmOnly,NoShutdown)
Electrical Trip(Alarm/OffLoadGenerator
FollowedByShutdown AfterCooling)
Shutdown(Alarm AndShutdown)
0-
1-
2-
3-
GeneratorOverCurrent Actions
Disable
Warning(AlarmOnly,NoShutdown)
Electrical Trip(Alarm/OffLoadGenerator
FollowedByShutdown AfterCooling)
Shutdown(Alarm AndShutdown)
0-
1-
2-
3-
9999
9999
9999
9999
9999
9999
kVA
kVA
kVA
kVA
0(dis)
0(dis)
0
0(dis)
0(dis)
0
Min
Default
Max
GeneratorUnder ShutdownPower
GeneratorUnder Pre-AlarmPower
GeneratorUnder Pre-AlarmResetPower
GeneratorOver ShutdownPower
GeneratorOver Pre-AlarmPower
dis
5
GeneratorOver Pre-AlarmResetPower
kVA
kVA
Under shutdownpower
Under prealarmpower
Under resetpower
Over shutdownpower
Over prealarmpower
Over resetpower
Unit
Shutdowndelaytime
Generator ShutdownDelay TimePower
GEN LEVEL ( )POWER Generator->Power level
0 99 2
Sec
dis
dis
0
dis
ReversePowerSet
ReversePower Action Delay Time
-9999
0(dis)
0
0
3
99
0
0(dis)
2
kW
Sec
ReversePower Actions
Disable
Warning(AlarmOnly,NoShutdown)
Electrical Trip(Alarm/OffLoadGenerator
FollowedByShutdown AfterCooling)
Shutdown(Alarm AndShutdown)
0-
1-
2-
3-
Reversepowerset
Reversepoweract.
Rv.pow.act.delaytime