EasyManua.ls Logo

Endress+Hauser Cerabar M PMC41 - Explanation of Terms

Endress+Hauser Cerabar M PMC41
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cerabar M
14 Endress+Hauser
Explanation of terms
Explanation of terms: turn down (TD),
set span and span based on zero point
Case 1:
Lower-range value (LRV)⏐ ≤ ⏐upper-range value
(URV)
Example:
Lower-range value (LRV) = 0 bar
Upper-range value (URV) = 0.5 bar
Nominal value (URL) = 1 bar
Turn down:
Nominal value/upper-range value (URV)=
1 bar/0.5 bar
TD = 2:1
Set span:
Upper-range value (URV) – lower-range value (LRV) =
0.5 bar – 0 bar
Set span = 0.5 bar
This span is based on the zero point.
P01-PMx4xxxx-05-xx-xx-xx-001
Example: 1 bar measuring cell
Case 2:
Lower-range value (LRV)⏐ ≤ ⏐upper-range value
(URV)
Example:
Lower-range value (LRV) = 0 bar
Upper-range value (URV) = 0.5 bar
Nominal value (URL) = 1 bar
Turn down:
Nominal value/upper-range value (URV)=
1 bar/0.5 bar
TD = 2:1
Set span:
Upper-range value (URV) – lower-range value (LRV) =
0.5 bar – 0 bar
Set span = 0.5 bar
This span is based on the zero point.
P01-PMx4xxxx-05-xx-xx-xx-002
Example: 1 bar measuring cell
Case 3:
Lower
-range value (LRV) ≥ ⏐upper-range value (URV)
Example:
Lower-range value (LRV) = –0.6 bar
Upper-range value (URV) = 0 bar
Nominal value (URL) = 1 bar
Turn down:
Nominal value/lower-range value (LRV) =
1 bar/0.6 bar
TD 1.67:1
Set span:
Upper-range value (URV) – lower-range value (LRV) =
0 bar – (–0.6 bar)
Set span = 0.6 bar
This span is based on the zero point.
P01-PMx4xxxx-05-xx-xx-xx-003
Example: 1 bar measuring cell
Set span
Span based on zero point
Nominal value i upper-range limit (URL)
Nominal measuring range
Sensor measuring range
LRL Lower-range limit
URL Upper-range limit
LRV Lower-range value
URV Upper-range value
0 bar
+1 bar
URLURV
LRL = LRV
0.5 bar
=
=
–1 bar
+1 bar
LRV
URLURV
0
LRL
0.5 bar
=
–1 bar
+1 bar
LRV
URLURV
0
LRL
–0.6 bar
=

Table of Contents