Cerabar M
4 Endress+Hauser
Function and system design
Device selection
Cerabar M –
product family
PMC41
P01-PMC41xxx-16-xx-xx-xx-000
PMC45
P01-PMC45xxx-16-xx-xx-xx-000
PMP41
P01-PMP41xxx-16-xx-xx-xx-000
PMP45
P01-PMP45xxx-16-xx-xx-xx-000
PMP46
P01-PMP46xxx-16-xx-xx-xx-000
PMP48
P01-PMP48xxx-16-xx-xx-xx-000
With capacitance measuring cell and
ceramic measuring diaphragm
(Ceraphire
®
)
With piezoresistive measuring cell and
metal measuring diaphragm
With piezoresistive measuring cell,
and diaphragm seal
Field of application Absolute pressure and overpressure
Process connections Threaded
connections
Flush-mounted
hygienic connections
Threaded
connections
Flush-mounted
hygienic connections
Hygiene diaphragm
seal, diaphragm seals
compliant with
ASME-BPE see
following section
"Overview of PMP46
diaphragm seals"
Flange diaphragm
seal, separator with
threaded connection
see following
section "Overview of
PMP48 diaphragm
seals"
Measuring ranges Up to 40 bar Up to 400 bar
Overpressure limit
(OPL)
1
Max. 60 bar Max. 600 bar
Process temperature
range
–40 to +100°C (–40
to +212°F)
–40 to +125°C
(–40 to +257°F),
+150°C (+302°F) for
1 h
–40 to +100°C
(–40 to +212°F)
–40 to +125°C
(–40 to +257°F),
+150°C (+302°F) for
1 h
-70 to +400°C (–40 to +212°F)
Ambient temperature
range
40 to +85°C (–40 to +185°F)
Maximum measured
error
±0.2% of set span
Optional: non-linearity ±0.1% of set span
±0.2% of set span
Supply voltage For non-hazardous areas: 11.5 to 45 V DC
EEx ia: 11.5 to 30 V DC
Output 4 to 20 mA, 4 to 20 mA with superimposed HART protocol, PROFIBUS PA
Options 3.1 Inspection
certificate
Materials
compliant with
FDA
Mounting bracket
–3.1 Inspection
certificate
Materials
compliant with
FDA
3.1 Inspection
certificate
Materials
compliant with
FDA
Mounting bracket
3.1 Inspection
certificate
–Materials
compliant with
FDA
3.1 Inspection certificate
Materials compliant with FDA
Temperature isolator
Electropolished surface
Mounting bracket
Specialties Flexibility thanks to modular design
Large selection of approvals, including ATEX, FM and CSA
Wide range of cable entries, cable glands and connectors
Choice of robust housing made of stainless steel (AISI 316L) or coated aluminum housing for strict hygienic requirements
Electropolished wetted surfaces
Dry ceramic cell (without fill fluid), resistant to abrasion and corrosion, compliant with FDA: Ceraphire
®
Special cleaning of the transmitter to remove paint-wetting impairment substances, for use in paint shops
1) Depends on the element of the selected components which has the lowest pressure rating