Ordering information
PMC41 This overview does not identify options which are mutually exclusive.
10 Approval:
R For non-hazardous areas
G ATEX II 1/2 G EEx ia IIC T6
F ATEX II 1 G EEx ia IIC T6
H ATEX II 2 G EEx ia IIC T6
N ATEX II 3 G EEx nA II T5
J ATEX II 1/2 G 1/2 D EEx ia IIC T6
K ATEX II 1/2 D EEx ia IIC T6
L ATEX II 1/3 D
C CSA General Purpose
S CSA IS, Class I, II, III Division 1, Groups A - G
T CSA Class II, III, Division 1, Groups E – G (Dust Ex), Class I, Division 2, Groups A – D
P FM IS, Class I, II, III, Division 1, Groups A – G
M FM DIP, Class II, III Division 1, Groups E – G
D IECEx Zone 1 Ex ia IIC T6
U NEPSI Ex ia IIC T6
Y Special version, to be specified
20 Housing; Electrical connection:
E1 316L; gland M20, IP 66
C1 316L; thread NPT 1/2, IP 66
G1 316L; thread G 1/2, IP 66
H1 316L; plug Han7D, IP 65
L1 316L; plug M12, IP 66 (in conjunction with absolute pressure sensors IP 68/NEMA 6P)
K1 316L; cable 5 m, IP 68 + atmospheric pressure compensation
E2 Alu; gland M20, IP 66
C2 Alu; thread NPT 1/2, IP 66
G2 Alu; thread G 1/2, IP 66
H2 Alu; plug Han7D, IP 65
L2 Alu; plug M12, IP 66 (in conjunction with absolute pressure sensors IP 68/NEMA 6P)
K2 Alu; cable 5 m, IP 68 + atmospheric pressure compensation
V2 Alu; valve plug M16 ISO4400, IP64
Y9 Special version, to be specified
30 Sensor range; MWP; OPL:
Sensor range MWP (maximum working
pressure)
OPL (overpressure limit)
Sensors for overpressure
1C 0 to 100 mbar/10 kPa/1.5 psi 2.7 bar/270 kPa/40 psi 4 bar/400 kPa/60 psi
1F 0 to 400 mbar/40 kPa/6 psi 5.3 bar/530 kPa/80 psi 8 bar/800 kPa/120 psi
1H 0 to 1 bar/100 kPa/15 psi 6.7 bar/670 kPa/100 psi 10 bar/1 MPa/150 psi
1M 0 to 4 bar/400 kPa/60 psi 16.7 bar/1.67 MPa/250 psi 25 bar/2.5 MPa/375 psi
1P 0 to 10 bar/1 MPa/150 psi 26.7 bar/2.67 MPa/400 psi 40 bar/4 MPa/600 psi
1S 0 to 40 bar/4 MPa/600 psi 40 bar/4 MPa/600 psi 60 bar/6 MPa/900 psi
Sensors for negative overpressure
5C –100 to 100 mbar/-10 to 10 kPa/
-1.5 to 1.5 psi
2.7 bar/270 kPa/40 psi 4 bar/400 kPa/60 psi
5F –400 to 400 mbar/–40 to 40 kPa/–6 to 6 psi 5.3 bar/530 kPa/80 psi 8 bar/800 kPa/120 psi
5H –1 to 1 bar/–100 to 100 kPa/–15 to 15 psi 6.7 bar/670 kPa/100 psi 10 bar/1 MPa/150 psi
5M –1 to 4 bar/–100 to 400 kPa/–15 to 60 psi 16.7 bar/1.67 MPa/250 psi 25 bar/2.5 MPa/375 psi
5P –1 to 10 bar/–0.1 to 1 MPa/–15 to 150 psi 26.7 bar/2.67 MPa/400 psi 40 bar/4 MPa/600 psi
Sensors for absolute pressure
2F 0 to 400 mbar/40 kPa/6 psi absolute 5.3 bar/530 kPa/40 psi 8 bar/800 kPa/120 psi
2H 0 to 1 bar/100 kPa/15 psi absolute 6.7 bar/670 kPa/80 psi 10 bar/1 MPa/150 psi
2M 0 to 4 bar/400 kPa/60 psi absolute 16.7 bar/1.67 MPa/250 psi 25 bar/2.5 MPa/375 psi
2P 0 to 10 bar/1 MPa/150 psi absolute 26.7 bar/2.67 MPa/400 psi 40 bar/4 MPa/600 psi
2S 0 to 40 bar/4 MPa/600 psi absolute 40 bar/4 MPa/600 psi 60 bar/6 MPa/900 psi
9Y Special version, to be specified
40 Calibration; Unit:
1 0.2% sensor range; mbar/bar
2 0.2% sensor range; kPa/MPa
3 0.2 % sensor range; mmmH
2
O/mH
2
O
4 0.2% sensor range; inH
2
O/ftH
2
O
5 0.2% sensor range; kgf/cm
2
6 0.2% sensor range; psi