Cerabar S PMP71 with 4 to 20 mA HART Identification
Endress+Hauser 7
Devices for use in hazardous areas are fitted with an additional nameplate.
P01-xMD7xxxx-18-xx-xx-xx-002
Fig. 2: Additional nameplate for devices suitable for use in hazardous areas
1 EC type-examination certificate number
2 Type of protection e.g. II 1/2 G Ex ia IIC T6
3 Electrical data
4 Safety Instructions number e.g. XA00235P
5 Safety Instructions index e.g. A
6 Date of device manufacture
Devices suitable for oxygen applications are fitted with an additional nameplate.
P01-xxxxxxxx-18-xx-xx-xx-000
Fig. 3: Additional nameplate for devices suitable for oxygen applications
1 Maximum pressure for oxygen applications
2 Maximum temperature for oxygen applications
3 Layout identification of the nameplate
Devices suitable for custody transfer applications are fitted with an additional nameplate.
P01-PMP71MID-18-xx-xx-xx-000
Fig. 4: Additional nameplate for devices suitable for custody transfer applications
1 Maximum pressure for liquid applications
2 Minimum pressure for liquid applications
3 Maximum pressure for gas applications
4 Minimum pressure for gas applications
Pmax
Tmax
for oxygen service
Bei Sauerstoffeinsatz/
3
1
2
tamb, max.+55°C tamb, min=-25°C
Pmin:
Pmin:
For liquid application:
Pmax:
Pmax:
For gas application:
SW Rev. 02.10.54
NMi Part Certificate TC7975
Checksum: 0xD8CC
1
2
3
4