Commissioning Deltabar FMD71, FMD72
46 Endress+Hauser
9.5.2 Configuring language via operating tool (FieldCare)
A0017654-EN
9.6 Measuring mode selection
L
WARNING
Changing the measuring mode affects the span (URV)
This situation can result in product overflow.
‣
If the measuring mode is changed, the setting for the span (URV) must be checked in
the "Setup" operating menu and readjusted if necessary.
Measuring mode (005)
Navigation Setup → Measuring mode
Write permission Operator/Service engineers/Expert
Description Select the measuring mode.
The operating menu is structured differently depending on the measuring mode selected.
Options • Pressure
• Level
Factory setting Level
9.7 Selecting the high-pressure side
9.7.1 Defining the high-pressure side
High press. side (183)
Navigation Setup → High press. side