Deltapilot S
44 Endress+Hauser
DB53 – cable version with
suspension clamp
For continuation of ordering information for DB53, see the following page.
10 Approval:
A Version for non-hazardous area
G ATEX II 1/2 G EEx ia IIC T6
H ATEX II 2 G EEx ia IIC T6
N ATEX II 3 G EEx nA II T6
S CSA IS, Class I, Division 1, Groups A – D
T CSA IS, Class I, Division 2, Groups A – D
20 Probe:
K … mm FEP extension cable (probe length: 0.5 to 200 m)
M mm PE extension cable (probe length: 0.5 to 200 m)
L … mm FEP extension cable for EEx ia, CSA IS (probe length: 0.5 to 100 m)
N … mm PE extension cable for EEx ia, CSA IS (probe length: 0.5 to 100 m)
30 Process connection:
70 Cable probe without suspension clamp
71 Suspension clamp AISI 316L
40 Measuring range:
BA 0 to 100 mbar/1 mH
2
O/40 inH
2
O
BB 0 to 400 mbar/4 mH
2
O/160 inH
2
O
BC 0 to 1200 mbar/12 mH
2
O/480 inH
2
O
BD 0 to 4000 mbar/40 mH
2
O/1600 inH
2
O
BE 0 to 10 bar/100 mH
2
O/4000 inH
2
O
50 Linearity; Fill fluid:
1 < 0.2 % of measuring range; FDA compliant
2 < 0.2 % of measuring range; inert oil
3 < 0.1 % of measuring range; FDA compliant
4 < 0.1 % of measuring range; inert oil
Z Additional specification
60 Measuring sensor seal:
1Viton
2EPDM
5Kalrez
3 Sensor welded
70 Electronics; Output:
Electronic inserts without integrated overvoltage protection
A Without integrated electronic insert (e.g. for ordering spare parts)
B FEB11, 3-wire analog signal
C FEB17, 2-wire PFM signal
E FEB22, 4 to 20 mA, HART
G FEB22, 4 to 20 mA, HART, with FHB20 onsite display
H FEB24, PROFIBUS PA
K FEB24, PROFIBUS PA, with FHB20 onsite display
1 FEB26, FOUNDATION Fieldbus
2 FEB26, FOUNDATION Fieldbus, with FHB20 onsite display
Electronic inserts with integrated overvoltage protection
M FEB11P, 3-wire analog signal
N FEB17P, 2-wire PFM signal
R FEB22P, 4 to 20 mA, HART
T FEB22P, 4 to 20 mA, HART, with FHB20 onsite display
U FEB24P, PROFIBUS PA
W FEB24P, PROFIBUS PA, with FHB20 onsite display