Installation iTEMP TMT82
12 Endress+Hauser
4.3.1 Mounting the head transmitter
1
2
3
4
5
6
7
9
8
1 2 3 4 5
1
2
3
4
120 mm
(4.72 in)
120 mm
(4.72 in)
Item A
Item B
Item C
A0014269-EN
 3 Head transmitter mounting (three versions)
Item A Mounting in a terminal head (terminal head flat face as per DIN 43729)
1 Terminal head
2 Circlips
3 Insert
4 Connection wires
5 Head transmitter
6 Mounting springs
7 Mounting screws
8 Terminal head cover
9 Cable entry
Procedure for mounting in a terminal head, pos. A:
1. Open the terminal head cover (8) on the terminal head.
2. Guide the connection wires (4) of the insert (3) through the center hole in the head
transmitter (5).
3. Fit the mounting springs (6) on the mounting screws (7).
4. Guide the mounting screws (7) through the side boreholes of the head transmitter
and the insert (3). Then fix both mounting screws with the snap rings (2).
5. Then tighten the head transmitter (5) along with the insert (3) in the terminal head.
6. After wiring→  17, close the terminal head cover (8) tightly again.